UPS ENERGY STORAGE SYSTEM


UPS ENERGY STORAGE SYSTEM
The Application scenario of the communication base station backup power supply
is the outdoor communication base station and the IDC machine room. In the
aspect of communication base station, there are many different products, like
48100, 4810 and 4875. And its working pattern is different. The competitive
edges are that small size, high voltage and big capacity--better traditional
lead-acid battery replacement choice, standard server size that can be built-in
19-inch rack--save room, wide operating temperature range, long service life
and independent development and production of single cells--make sure
consistency performance of cells.  
INQUIRY NOW
PARAMETERS OF UPS ENERGY STORAGE SYSTEM
No. Item SPEC.
48100
1 Capacity/kWh 4.8kWh
2 Rated Voltage/V 48
3 Material LFP
4 Standard Discharge Current/A 0.2C
5 Max. Continuous Discharge Current 1C
6 Standard Charge Current 0.2C
7 Max. Continuous Charge Current 1C
8 Cycle Life ≥1500
9 Communication Mode RS232,RS485
10 Operating Temperature Range Charge 0-45℃
Discharge -20-60℃
11 Applicable Standard UL, IEC62619, UN38.3


No. Item SPEC.
1 Module Specifications 12S2P (0.5C) 8S3P (0.3C)
2 Rack Series And Parallel 180S2P (15 modules+1 high-pressure
box) 184S3P (23 modules+1 high-pressure box)
3 System Series And Parallel 180S12P (6 racks parallel) 184S12P
(4 racks parallel)
4 Rated Capacity 300Ah/1800Ah 450Ah/1800Ah
5 Rated Voltage DC576V DC588.8V
4 Working Voltage Range 450V~657V 460V~671.6V
5 Operating Voltage Range 522V~639V 533.6V~653.2V
6 Rack Rated Energy 172.8KWh 264.96KWh
7 System Rated Energy 1036.8KWh 1059KWh

UPS BATTERY COMPETITIVE EDGES
The application area is the outdoor communication base station and the IDC
machine room. And there are four working patterns, that is pattern 1 normal
electric supply, pattern 2 overrun electric supply voltage, and frequency,
pattern 3 out of electric supply, and pattern 4 UPS system fault. The 48100
Backup Power of Communication Base Station whose cycle life is over 2000 times.
Small size, high voltage, and big capacity--better traditional lead-acid
battery replacement choice.
Standard server size that can be built-in 19-inch rack--save room.
Wide operating temperature range.
Long service life.
Independent development and production of single cells--make sure consistency
performance of cells.

If you want to know more about lithium ion ups for home, please leave us a
message.

As one of lithium battery suppliers china, we have types of chinese lithium
batteries for sale, more details, please visit our website.