Testing EquipmentHome > Offers to Sell > Industrial Machinery & Equipment > Measuring & Analyzing Instruments > Testing Equipment
1/10/22 7:41 GMT
Dynamic Foam Testing System
This equipment is our updated version, it is an all-in-one machine that can do both hardness test, fatigue test, and integrated test in accordance with the ASTM D3574, ISO 2439, IDO 3385 standards. Users can evaluate the properties changes of the foam material occurring in the long-term use. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Great Safe Apparatus Limited
Dongguan, Guangdong, China Guangdong 523000 China 1/10/22 7:32 GMT
Foam Rebound Tester
This machine is designed for the determination of the rebound elasticity of the foam materials applied in ASTM D3574, ISO 8307, JIS 6400. This instrument through a given diameter and the quality of steel ball in the specified height on free falling on the foam sample, calculate the spring back of the maximum height of steel ball and ball drop height ratio is the percentage of spring rate, expressed as a resilient rate of foam plastics can rebound resilience. This machine adopts a microprocessor to control, LCD display and can print test data. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Great Safe Apparatus Limited
Dongguan, Guangdong, China Guangdong 523000 China 12/29/21 2:58 GMT
ISO4210 IEC Test Equipment Electric Bicycle Concrete Road Pavement 200V Tes
Standard:GB17761-2018 Clause 7.2.1,Clause 7.2.2 , Clause 7.2.4, ISO4210. Application: This tester is used for the detection of electric bicycle speed limit and pedal riding ability. According to the relevant requirements of GB17761-2018, GB3565-2005 and other standards, the safety performance and energy consumption of electric bicycles and other products are tested. The data can be stored and transmitted. The test parameters include deceleration, speed, time, distance, force, current, voltage, and so on. Operating conditions: 1,Test environment: -5 °C ~ 35 °C, wind speed <3m / s. 2,Test road: 1) Road pavement: concrete road pavement. 2) Road size: 3m (length) * 2m (width) * 20cm (thickness). 3) Friction coefficient between dry road surface and electric bicycle tire: minimum 0.5. 3,Cycling staff weight: total mass ≤ 75Kg. Parameters: 1,It can test the safety performance of electric bicycle according to the requirements of GB17761-2018, voltage collection range: 24V/36V/48V, 48V/60V/72V. 2,The electric bicycle braking performance test can be carried out in accordance with the requirements of GB3565-2005. 3,The driving mileage test can be carried out as required. 4,A variety of test methods to meet the vehicle speed measurement of the vehicle's static state. 5,The electric bicycle safety performance test can be carried out in accordance with the requirements of GB17761-2018. 6,Instrument accuracy: ±2% (provided in the response file to provide proof of the technical parameters (manufacturer color pages or manuals or product manuals)). 7,Measuring range: NO. Item Range 1 Speed 0.5~200.0km/h 2 Distance 0~20000m 3 Time 0~99999s 4 Force hand brake 0 ~ 200N 5 Current 0~100A 6 Voltage 0~200V (Provided materials (manufacturer color pages or instruction manuals or product manuals) that reflect this technical parameter are provided in the response file) 8,Test parameter resolution: NO. Item Resolution 1 Speed 0.01km/h 2 Distance 0.01m 3 Time 0.01s 4 Force 0.1N 5 Current 0.1A 6 Voltage 0.1V The main configuration: 1,1 set of professional version test software 2,Control display device 1 PC 3,GPS sensor 1 Set 4,Speed sensor 1 Set 5,Brake operating force component 1 Set 6,Current sensor 1 Set 7,Control computer 1 PC 8,Brake spray device 1 Set 9,Test accessory 1 Set 10,Import VBOX II SX (RLVB2SX) road vision 1 PC ISO4210 IEC Test Equipment Electric Bicycle Concrete Road Pavement 200V Tester With Friction Coefficient Of 0.5 0 Contact:
Phone: Fax: Email: GUANGZHOU HONGCE EQUIPMENT CO., LTD.
BLDG D2, Jinhe Industrial Park, Dashi Street, Panyu, Guangzhou, Guangdong Guangzhou 510000 China 12/28/21 3:50 GMT
ISO 16750-4 Auto Parts Test Equipment Splash Water And Submersion Test Cham
Product Description ISO 16750-4 Auto Parts Test Equipment Splash Water And Submersion Test Chamber Standard: ISO16750-4 Road vehicles-Environmental conditions and testing for electrical and electronic equipment-Part 4: Climatic loads, clause 5.4.2 Ice water shock test. VW-80000 Electric And Electronic Components In Motor Vehicles up to 3.5t General Requirements, Test Conditions and Tests clause 9.12 K-12 Temperature Shock With Splash Water; GB/T 28046.4-2011 Auto Parts Test Equipment Purpose: This test simulates a thermal shock induced by ice water and applies to products in the splash areas of the vehicle. The purpose of this test is to simulate ice water splashing over a hot system/component. This happens when driving on wet roads during the winter. Failure modes are mechanical cracking of materials or seal failures caused by different temperature expansion coefficients. It is a reliability test equipment for various kinds of electronic, electrical, plastic and other raw materials and devices for cold resistance, heat resistance, ice water splash resistance test, ice water immersion resistance test and quality control engineering reliability test equipment. Test method: Splash water test: Heat the DUT in a hot air oven at T max for the specified holding time, t h . Then splash the DUT with ice water for 3 s. If the DUT is splashed in the vehicle from only one direction, splash it from this direction only while it is in an as-installed position. If the equipment is splashed from various directions in the vehicle, then these directions shall be taken into account. In this case, use a new DUT for each splash direction. The width of the splash directed at the DUT shall always be greater than the width of the DUT. If the DUTs to be splashed prove too big for one jet, arrange several jets in a row to produce a line of splash impact on the DUT. See Figures 4 to 6. Test parameters include: ⎯ number of cycles: 100; ⎯ holding time, t h , at T max : 1 h or until DUT temperature stabilization is reached; ⎯ transition duration: < 20 s (for manual transition of DUT between temperature storage and splashing); ⎯ test fluid: de-ionized water; ⎯ water temperature: 0 °C to +4 °C; ⎯ water flow: between 3 l and 4 l per 3 s (splash duration); ⎯ distance between jet and DUT surface: (325 ± 25) mm (water shall be applied over the complete width of the DUT); ⎯ operating modes: see Figure 5; ⎯ orientation of the DUT: as in the vehicle. Auto Parts Test Equipment Submersion test: Connect the DUT to the test equipment. Operate the DUT in a hot air oven at T max for the specified holding time, t h. With the device still operating, submerge it for 5 min in an ice water tank at least 10 mm deep. Test parameters include: ⎯ number of cycles: 10; ⎯ holding time, t h , at T max : 1 h or until DUT temperature stabilization is reached; ⎯ transition duration: < 20 s; ⎯ test fluid: de-ionized water; ⎯ water temperature: 0 °C to +4 °C; ⎯ immersion time: 5 min; ⎯ operating mode: 3.2 in accordance with ISO 16750-1; ⎯ orientation of the DUT: as in the vehicle. Parameter: Inner size 1000*1000*1000mm Outer size 1650*1800*2300mm Submersion area size 500*500*500mm Jet qty. 1 Jet position Right side of the inner chamber Distance between jet and DUT surface 325 ± 25 mm (Can be adjusted manually) Jet water flow 3-4L/3S Water temperature control range 0-+4°C Temperature range RT+10°C -150°C Cooling rate 25°C-2°C≤60min Heating rate RT+10°C -150°C≤45min Injection time per cycle (30min) 3S, interval time: 29m57s (touch screen setting) Cycle 100times (touch screen setting) ISO 16750-4 Auto Parts Test Equipment Splash Water And Submersion Test Chamber 0 Contact:
Phone: Fax: Email: HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
101, building D2, Huanghe science and Trade Industrial Park, Shibei Industrial Avenue, Huijiang, Das Guangzhou 510000 China 12/28/21 2:01 GMT
JUNSUN 100KV AC&DC High Voltage Divider
1. High precision Uses high precision HV thin-film capacitor and HV glass glaze resistor, input impedance is high, lower the measured current, small power consumption, improves the accuracy and stability of the device. For signal processing, adopts high performance OP to amplify the signal, uses the newest dual integrating A/D sampling technique, four and half LCD display, the maximum resolution up to 0.001kV, it is the replacement products for HV electrostatic voltmeter. 2. Good anti-jamming performance. Adopts special shield technique. equipotential ball uses aluminum, effectively improves the electric field distribution around the equipotential ball, prevents the point discharge, improves the anti-jamming ability of the test results. LV display meter is full metal enclosed instruction to shield, Coaxial cable connect the HV divider and LV display meter, reduce the effects to indicating value by high voltage, then realize high stability, high linearity. 3. Safe and reliable. This device is composed by HV divider and LV display meter, the HV divider uses America Dupont packing material, special technique to embed, with smaller structure, lighter weight, lower the internal partial discharge to the least, more reliable, do not leak oil. Coaxial cable connect the HV divider and LV display meter when working, the HV and LV parts are far away from each other, safe and reliable. 4. Easy to operate. Uses toggle switch to shift HV/LV, AC/DC, convenient and swift. Four and half LCD directly display the test results, easy and clear. Bring great convenience for field tests. 5. Convenient to carry. Portable structure, the whole machine use aluminum alloy package as case, can easily to disassemble. Small in volume, light in weight, convenient to carry and use. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 12/22/21 2:20 GMT
Dry Type AC/DC Hipot Test Set 5KVA/50KV Booster Hipot Testing Transformer
This series of testing transformer uses advanced production equipment, adopts the new technology of coil winding epoxy vacuum casting and CD type iron core. Compared with similar oil-immersed transformers, it significantly reduces the weight and volume, improves the insulation strength and humidity resistance, and effectively weakens the magnetic flux leakage and greatly strengthens the transformer's ability to withstand the impact of the test short-circuit current. This series of testing transformer can also make DC high voltage test by using a matched high-voltage silicon stack. This series of testing transformer have features of light weight, small volume, beautiful appearance, stable performance, convenient usage and carrying, especially suitable for site operation, are new generation high voltage testing transformer used for AC and DC in China. This series of testing transformer are applicable to power system and all power users to detect on site the insulating performance test of all electrical equipment, high voltage power sources of all appliance's voltage system or equipment with DC high voltage small current. TECHNICAL TARGET: 1. Impedance voltage: 4.5%-8% 2. Output voltage waveform: sine wave 3. Surface temperature rise: <55℃ 4. No-load loss consumption: 0.2% - 0.35% 5. Allowable continuous operation time: 2 hours 6. Interrupted operation time: continuous Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 12/20/21 2:43 GMT
JSDY-021 Transformer Oil Insulating Liquids 0-80KV Breakdown Voltage Tester
1. High accuracy, long service life. 2. The test process is fully in compliance with the requirements of IEC 60156. 3. User-defined test. 4. Proof test. 5. The test process and result is displayed in real time on the LCD screen. 6. All parameters of the test process can be set. 7. The built-in EEPROM memory can save up to 100 groups of test data and results. 8. The built-in micro-printer can print the test results at any time. 9. All the human-machine interaction operations can be completed by rotating the mouse. 10. RS232 interface, upload test data to computer and make Word format test report. 11. Calibration interface available. 12. The tester is easy to operate, powerful, stable and reliable, and it has an excellent anti-interference ability. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 12/15/21 2:42 GMT
Dry Type AC/DC Hipot Tester/ 10KVA Testing Transformer
This series of testing transformer uses advanced production equipment, adopts the new technology of coil winding epoxy vacuum casting and CD type iron core. Compared with similar oil-immersed transformers, it significantly reduces the weight and volume, improves the insulation strength and humidity resistance, and effectively weakens the magnetic flux leakage and greatly strengthens the transformer's ability to withstand the impact of the test short-circuit current. This series of testing transformer can also make DC high voltage test by using a matched high-voltage silicon stack. This series of testing transformer have features of light weight, small volume, beautiful appearance, stable performance, convenient usage and carrying, especially suitable for site operation, are new generation high voltage testing transformer used for AC and DC in China. This series of testing transformer are applicable to power system and all power users to detect on site the insulating performance test of all electrical equipment, high voltage power sources of all appliance's voltage system or equipment with DC high voltage small current. TECHNICAL TARGET: 1. Impedance voltage: 4.5%-8% 2. Output voltage waveform: sine wave 3. Surface temperature rise: <55℃ 4. No-load loss consumption: 0.2% - 0.35% 5. Allowable continuous operation time: 2 hours 6. Interrupted operation time: continuous Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 12/14/21 3:54 GMT
JSBC-901 Series Fully Automatic Transformer Turn Ratio Tester TTR Test Set
FUNCTIONS: 1. The voltage ratio measurement of three or singe phase transformer 2. The group vector measurement of three phase transformer. 3. The polarity measurement of single phase transformer or CT/PT (CT that knee-point voltage should be more than 80V). 4. Voltage ratio error calculation. 5. Voltage ratio range calculation of three phase transformer. 6. Current transformer ratio measurement. 7. Excitation current measurement in ratio testing. 8. Reproduction the AC test voltage from power source to reduce the effects of bad power source. 9. Save the test results in the memory internal the tester. 10. Print the test results by micro printer. 11. Reverse connection detect unit to prevent the high voltage injected to the operator. 12. Over current protection unit integrated in software and hardware. 13. Upload the test results to PC by RS232 and make word report by software. TECHNICAL INDEX: 1. Ratio measurement range: 1 ~ 10000 2. Group measurement: 1 ~ 12 3. Phase measurement error: 1 degree 4. Ratio measurement error: 1 ~ 2000 ± 0.2%RDG 2000 ~ 10000 ± 0.5%RDG 5. Test voltage: 0 ~ 80V 6. Power supply: AC220V ± 10%, 50Hz/60Hz 7. Size: 400 × 350 × 200 MM 8. Weight: 7 KG 9. Humidity: ≤85%RH 10. Third party official calibration certificate can be provided. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 12/9/21 2:07 GMT
IEC62262 IK07 IK10 Mechanical Vertical Impact Test Apparatus
IEC62262 IK07-IK10 Mechanical Vertical Impact Test Apparatus Product Introduction: The IK07-IK10 Mechanical Vertical Impact Test Apparatus is designed and manufactured according to the standard requirements of IEC60068-2-75, IEC60598-1, IEC62262 and etc. It is used for the impact resistance test of the enclosures of household and similar electronic and electrical products and their accessories, luminaires, etc., to assess the safety performance and strength level of the products. The principle is that the striking element is free released at a certain height through a 1 m pendulum tube, impact the specimen at the lowest point in the vertical direction, after the conversion of gravitational potential energy to kinetic energy, to achieve the purpose of impact test on the sample. Technical Parameters: Standard IEC62262 Energy / J 2, 5, 10, 20 and 50J are optional Striking Elements (Equivalent Mass) 500g,1.7kg,5 kg,5 kg,10 kg, please refer to the following table 1 Conduit Each striking element is equipped with a dedicated conduit Impact Point The device has X and Y axis guides to move the release device over the entire bottom area Height of Impact Point 0-1000mm, electric adjustable Height of Fall Please refer to table 2, fixed by the conduit Release Method Electromagnet release Bottom Plate Nylon base plate thickness 8mm, hardness HRR85- 100,1000m×1000m Relationship of IK code and corresponding energy : IK Code IK07 IK08 IK09 IK10 Energy / J 2 5 10 20 Note 1. If higher impact energy is required, the recommended value is 50J. Note 2: Some other standards use a single digit to indicate the specified impact energy. To avoid mixing with it, the feature number is represented by two digits. an unprotected according to this standard IEC62262 IK07 IK10 Mechanical Vertical Impact Test Apparatus 0 Contact:
Phone: Fax: Email: Sinuo Testing Equipment Co. , Limited
#301, Building 2, No. 123 of Zhongsheng Road, Zhongcun Street, Panyu District, Guangzhou Guangzhou 510000 China 12/2/21 9:17 GMT
New Design Salt Fog Price Corrosion Test Chamber With Humidity Control With
New design Salt Fog Price Corrosion Test Chamber With Humidity Control with CE certificate Product Uses The brine spray test machine is to test the corrosion resistance of all kinds of surface treatment, including coating, electroplating, organic and inorganic leather, anodic treatment, antirust oil and other anticorrosive treatments. Structure of the machine body: A. The laboratory uses P.V.C polyvinyl chloride plate, acid and alkali resistant, easy to clean.(Germany (aless) B. The laboratory seal cover is made of transparent impact resistant acrylic board.(Germany NSP) C. The laboratory seal cover is made of transparent impact resistant acrylic board. D. Saturated air pail adopts SUS#304 stainless steel high pressure tank for best insulation effect. E. Laboratory blue frame adopts plane indexing frame. According to the standard, the angle is 20°±5°, the fog falls on all sides and the fog is identical. The number of test pieces is large. 3.Specification parameter list of salt spray test machine: Model BT-HY-60 BT-HY-90 BT-HY-120 BT-HY-160 BT- HY-200 Inner box size: 60*45*40 90*60*50 120*100*50 160*100*50 200*100*50 (L×W×H) cm Outside box size: 108*108*65 135*112*75 190*128*125 230*128*125 270*128*125 (L×W×H)cm Temperature range 35℃~55℃; Test chamber temperature NSS ACSS 35℃±1℃(CASS 50℃±1℃) Saturated air barrel temperature NSS ACSS 47℃±1℃(CASS 63℃±1℃) Temperature fluctuations ≤±0.5°C Temperature uniformity ≤±2.0°C Lab volume 110L 270L 600L 800L 1000L Brine tank capacity 15L 25L 40L 65L 80L Multiple safety protection devices Water shortage; over temperature ;phase protection Standard accessories Test salt, measure bucket, tool etc 1 set weight (kg) 60 90 180 280 450 Power AC220V 1Φ20A AC220V 1Φ20A AC220V 1Φ30A AC220V 3Φ15A AC220V 3Φ15A Detailed Images New design Salt Fog Price Corrosion Test Chamber With Humidity Control with CE certificate New Design Salt Fog Price Corrosion Test Chamber With Humidity Control With CE Certificate 1 Contact:
Phone: Fax: Email: BOTO GROUP LTD
Room 2304, Fortune Plaza, No. 5616 Caoan Road, Anting Town, Jiading District, Shanghai Shanghai 200000 China 12/2/21 2:23 GMT
IIJ Transformer Oil BDV Tester Oil Breakdown Strength Test Equipment 80 kV
IIJ-II Series Transformer Oil Breakdown Voltage Tester is specially designed for testing the breakdown voltage (dielectric strength) of transformer oil. It is also suitable for testing other mineral or silicone insulating oils. Breakdown voltage testing of insulating oils can help to assess the condition of these oils within electrical equipment, such as transformers, capacitors, switches, etc. Based on the test results, the oil can be identified as aged due to an increase in water content, sludge, or if the oil has oxidized. IIJ-II Series Transformer Oil Breakdown Voltage Tester is suitable for laboratory use as well as field use. It fully automatically tests the electrical breakdown voltage of insulating oils in compliance with international standard IEC-60156. This tester adopts industrial single-chip control system, large-scale integrated circuit, new-style I/O interface, and unique detection and anti-interference technology, which greatly improve its reliability and functionality. TECHNICAL DATA: 1. Power supply: AC220V±10%, 50HZ 2. Output voltage: 80KV, 100KV 3. Capacity: 1.6KVA, 2.0KVA 4. Speed of voltage increase: about 2KV/S 5. Voltage detection accuracy: 3% 6. Breakdown sensitivity: <2KV 7. Waveform distortion: ≤3% 8. Breakdown response time: ≤10MS 9. Polar distance: 2.5MM 10. Operational environment: Temperature: 0℃ - 40℃. Humidity: ≤85%RH 11. Storage environment : Temperature: -20℃ - 40℃. Humidity: ≤75%RH 12. Working altitude: <1500M (if over 1500m can be designed specially) 13. Packing: Wooden case Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 11/30/21 2:54 GMT
Automatic Cycling Water Lab Climate Test Chamber 80L To 1000L Temperature H
PRODUCT DESCRIPTION Liyi 80L To 1000L Environmental Lab Climatic Test Equipment Chamber Temperature Humidity Cycling Chambers Product introduction: This Automatic Cycling Water Lab Climate Test Chamber 80L To 1000L Temperature Humidity Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material. Standards: GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 etc. Specification: Model LY-280 LY-2150 LY-2225 LY-2408 LY-2800 Inner Size W×H×D(cm) 40×50×40 50×60×50 60×85×80 60×85×80 100×100×80 Outside Size W×H×D(cm) 93×155×95 100×148×106 117×166×91 140×176×101 170×186×111 Volume (V) 80 L 150L 225L 408L 800L Temp and Hum Range A:-20°C~150°C B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C RH20%-98% Function Fluctuation ±0.5°C ±2.5%RH Deviation ±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH) Controller Analytical Accuracy ±0.3°C ±2.5%RH Wind Cycling Way Centrifugal fan-broadband type forced air circulation Refrigeration Way Single stage compression refrigeration Refrigerator French Tecumseh Refrigerants R4O4A USA DuPont environmental protection refrigerant(R23+R404) Condensing Way Air-cooled or water-cooled Water Supplying Way Automatic cycling water supply Standard Accessories 1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 clapboards, 1 bag of wet and dry bulb, 3 fuses, 1 power line. Safety device Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system Standard configuration ●Stainless steel exterior ●Energy-efficient refrigeration with exclusive electronic expansion valve system ●Specialized humidity generation and control ●Unique thermal break construction for extreme testing ●Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m ●No fuse breaker, over pressure,over heat and over current protection for compressor, Over temperature protection, over load protect of blower, dry heat protection Contact:
Phone: Fax: Email: Dongguan Liyi Environmental Technology Co., Ltd.
No.2, Zhifu Road, Mowu, Wanjiang District, Dongguan, Guangdong, China Dongguan 523000 China 11/29/21 8:06 GMT
100KV Transformer Oil/ Insulating Fluids Dielectric Strength Testing Kit
IIJ-II Series Transformer Oil Breakdown Voltage Tester is specially designed for testing the breakdown voltage (dielectric strength) of transformer oil. It is also suitable for testing other mineral or silicone insulating oils. Breakdown voltage testing of insulating oils can help to assess the condition of these oils within electrical equipment, such as transformers, capacitors, switches, etc. Based on the test results, the oil can be identified as aged due to an increase in water content, sludge, or if the oil has oxidized. IIJ-II Series Transformer Oil Breakdown Voltage Tester is suitable for laboratory use as well as field use. It fully automatically tests the electrical breakdown voltage of insulating oils in compliance with international standard IEC-60156. This tester adopts industrial single-chip control system, large-scale integrated circuit, new-style I/O interface, and unique detection and anti-interference technology, which greatly improve its reliability and functionality. MAIN FEATURES 1. Easy operation, high automation, only need to press button once and all work done automatically. 2. Menu management, data input simple and convenient. 3. It can store 99 sets of oil sample test data, which is convenient for future reading and printing. The test data can be saved when the power is turned off. 4. The system clock can continue to run even when the power is off (the internal time of this system is for reference, not for standard timing). 5. Strong anti-interference ability, high testing precision. 6. Small size and light weight, convenient for field operations. Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China 11/23/21 2:27 GMT
IIJ-II-100 Transformer Insulating Oil Breakdown Voltage Tester
IIJ-II Oil Breakdown Voltage Tester is produced by our company, which adopts industrial single plate integrated circuit, new-style I/O jack, with unique inspection and anti-jamming technology to greatly improve its reliability and functionality. Main features: 1. Easy operation, high autoimmunization (only press button once and all work done automatically) 2. Menu management, data input simple and convenient 3. It can store 99 data of oil sampling tests, the test data can be reviewed and printed in 100 years even after power is off. 4. The clock in going on after power off. (The internal time of the system just for test reference, not for standard time) 5. The software can be upgrade through RS232 terminal. 6. Strong anti-jamming, high precision testing. 7. Small measurement, light weight, and convenient for outdoor operation. Technical parameter: 1. Power supply: AC220V ±10%, 50Hz 2. Output voltage: 80kV, 100kV (100kV can be manufactured to order in advance) 3. Capacity: 1.6kVA, 2.0kVA 4. Speed of voltage increase: about 2kV/S 5. Voltage inspection accuracy: 3% 6. Breakdown sensitivity: <2kV 7. Waveform distortion: ≤3% 8. Breakdown response time: ≤ms 9. Working environment: temperature: 0C~40C, humidity: max relative humidity 85% 10. Storage environment: temperature: -20C ~ 60C, humidity: max relative humidity 75% 11. Work height: <1500m (if over 1500m, it can be customized) Minimum Order: 1 bags Contact:
Phone: Fax: Email: Chongqing Junsun Mechanical & Electrical Co., Ltd
No. 33 Xijiao Road, Jiulongpo District Chongqing 400050 China SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
© 1996-2024 IMEXBB.com. All rights reserved.
|
|