Insulation, Accessories & OthersHome > Offers to Sell > Electronics & Electrical > Insulation, Accessories & Others
11/1/21 7:58 GMT
ABB DO810
CONTACT Phil Email: sales5@askplc.com Mobile: +86-18020714492 Skype: sales5@askplc.com Wachat: 18020714492 Shipment: EMS,DHL,UPS & FEDE , X Payment: T/T Supply Ability: 30 Unit/Units per Month Price: The more you order ,the lowe , r price you will get Delivery: In stock,w , ithin 3 days send the products About us Our office is located in Xiamen Fujian, China, cooperate with original manufacturer directly; Equipped with a professional sales team, own engineer for technical support and good after-sale service; Large inventory with original product quality for fast delivery. These help us become as a strong supporter of our clients: providing solution for the end-user, and also ensuring profits for the re-seller. Q&A 1.Q: How about the warranty ? A: Moore provide 12 months warranty for all the goods from us , and you can refund the goods with any quality problem in 15 days. 2.Q: Other supplier have a better price than yours. A: "To create more benefit fir clients"is our belief, if you have a better price , please let Moore know , we will try best to meet your price and support you. 3.Q: We have not cooperation before , how we can believe you ? A: For our first order , you can pay after we prepare the goods. 4.Q: What about shipment ? A: We have DHL,UPS,TNT... with competitive price , of course , customers can also use their own freight forwarders. More modules GE Modules IC 697 RCM711 IC 695 PSD140 IC 695 ALG728 IC 697 PWR724 IC 695 PSD040 IC 695 ALG708 IC 697 PWR711 IC 695 PSA140 IC 695 ALG628 IC 697 PWR710 IC 695 PSA040 IC 695 ALG626 IC 697 MDL940 IC 695 PNC001 IC 695 ALG626 IC 697 MDL750 IC 695 PBM300 IC 695 ALG616 IC 697 MDL740 IC 695 NIU001 IC 695 ALG608 ABB MODULES ABB DSQC697 ABB DSQC626 ABB DSQC652 ABB DSQC688 ABB DSQC612 ABB DSQC643 ABB DSQC679 ABB DSQC611 ABB DSQC639 ABB DSQC668 ABB DSQC604 ABB DSQC627 ABB DSQC664 ABB DSQC602 ABB DSQC661 ABB DSQC663 ABB DSQC662 ABB DSQC655 Foxboro ; Triconex , Westinghouse, Rockwell Allen-Bradley; Reliance ; Siemens ; Motorola ; Honeywell TDC2000/3000 et. If you have any PLC DCS inquiries, please contact us freely. It will be a comfortable and happy business cooperation Minimum Order: 1 bags Contact:
Phone: Fax: Email: Moore Technology Co. LTD
32D floor,Guomao building,Hubin South Road,Siming District,Xiamen City,Fujian Province,China. XIAMEN 361009 China 10/8/21 3:05 GMT
PRE-TERMINATED MULTIFIBER CABLE
PRE-TERMINATED MULTIFIBER CABLE Pre-terminated multifiber cable consist of optical fiber cable terminated with various types of connectors, such as the ST, FC, SC, LC, MU, MTRJ, E2000 Connector types. Our polishing craft and expertise ensure excellent optical performance. As a professional pre terminated cable manufacturer, T&S produces multifiber cable assemblies that are composed of top-quality ceramic ferrules and fiber connector housings. All of our multifiber cables are ensured with a stable performance at a high-quality level. FAQs of Pre-terminated Multifiber Cable What Is The Default Length Of Both Fanout Part (breakout Leg) And The Entire Length? Can It Be Customized? No default length is defined and you can customize the multifiber cable for sure. In most cases, the breakout leg is 0.5m according to our record. The longest breakout leg could be 3.0m or longer and it depends. Will A 50m Pre-terminated Cable Be Shipped With Being Pack On A Spool? What's The Largest Fiber Count Of Pre-terminated Multi-fiber Cable T&s Can Offer? How Much Does It Cost To Terminate Fiber Optic Cable? T&S Communications is a professional fiber optic accessories suppliers, we provide pre terminated fiber optic cable, pre terminated fiber and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 3:05 GMT
WAFER
PLC WAFER As an experienced plc splitter factory, T&S offers PLC splitter wafers as well. Based on Planar Lightwave Circuit technologies, PLC splitter wafers are produced on the quartz substrate through a series of processes including CVD deposition, photo-masking, etching, etc. PLC splitter wafers can be designed for 1x2, 1x4, 1x8, 1x16, 1x32, 1x64 and 2xN. Splitter chips with high yield, quality and reliability, are made of PLC wafers through dicing and polishing. Specifications of PLC Wafer Optical SpecificationsWafer Specifications Parameter Class Unit 1x2 1x4 1x8 1x16 1x32 1x64 Operating Wavelength - nm 1260-1650 Insertion Loss P dB 3.6 6.7 9.8 13.2 16.2 19.8 PDL P dB 0.15 0.15 0.2 0.25 0.25 0.3 Uniformity P dB 0.5 0.5 0.6 0.8 1.0 1.2 Return Loss - dB - ≥55 Directivity - dB - ≥55 Operating Temperature - ℃ - -40~+85 Storage Temperature - ℃ - -40~+85 TS Communication is a professional fiber optic accessories suppliers, we provide plc splitter 1x32, 1x16 plc splitter and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 3:02 GMT
QSFP+ 40G LR4 10KM
QSFP+ 40G LR4 10KM The QSFP+ 40G-LR4-10km module is a highly integrated 4x10G transceiver focused on reach, bandwidth, density and cost for high port-count 40G systems, and client-side 40G interfaces. The 40G QSFP+ LR4 Lite transceiver is designed for applications based on the IEEE802.3ba 40GBASE-LR4 standard of up to 10km reach. Features of QSFP+ 40G LR4 10km Reach: 10 km via SMF Uncooled CWDM DFB lasers, directly modulated Using ITU G.694.2 wavelength grid at 1271, 1291, 1311, and 1331nm User controllable Transmit Input Equalization and Receiver Output Amplitude MSA-compliant performance monitoring via I2C interface Fiber connector: SMF LC duplex connector Compliant with QDR/DDR InfiniBand data rates Hot-pluggable electrical interface 0–70°C operating temp Power dissipation < 3.5W RoHS6 compliant (lead-free) Applications of QSFP+ 40G LR4 10km 40G Ethernet InfiniBand QDR and DDR interconnects Specifications of QSFP+ 40G LR4 10km Recommended Operating EnvironmentOptical Transmitter PerformanceOptical Receiver Performance Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. Parameter Symbol Min Typical Max Unit Power Supply Voltage VCC 3.135 3.300 3.465 V Operating Case Temperature TC 0 25 70 °C Pin Descriptions of QSFP+ 40G LR4 10km Pin Definition of QSFP+ 40G LR4 10km Pin Symbol Name/Description 1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non-Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non-Inverted Data Input 7 GND Ground 8 ModSelL Module Select 9 ResetL Module Reset 10 Vcc Rx +3.3 V Power supply receiver 11 SCL 2-wire serial interface clock 12 SDA 2-wire serial interface data 13 GND Ground 14 Rx3p Receiver Non-Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rx1p Receiver Non-Inverted Data Output 18 Rx1n Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 22 Rx2p Receiver Non-Inverted Data Output 23 GND Ground 24 Rx4n Receiver Inverted Data Output 25 Rx4p Receiver Non-Inverted Data Output 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx +3.3 V Power supply transmitter 30 Vcc1 +3.3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non-Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Tx1p Transmitter Non-Inverted Data Input 37 Tx1n Transmitter Inverted Data Input 38 GND Ground Important Notice of QSFP+ 40G LR4 10km Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by T&S before they become applicable to any particular order or contract. In accordance with the T&S policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of T&S or others. Further details are available from any T&S sales representative. T&S Communications is a professional fiber optic products supplier, we provide plc splitter 1x32, qsfp transceiver module, qsfp transceivers and etc. Want to know qsfp price or more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 3:01 GMT
QSFP28 100G SR4 100M
QSFP28 100G SR4 100M The QSFP28 100G-SR4-100m module is a highly integrated 4x25G transceiver focused on reach, bandwidth, density and cost for high port-count 100G systems, and client-side 100G interfaces. Each lane can operate at 25Gbps up to 70m using OM3 fiber or 100m using OM4 fiber. These modules are designed to operate over multimode fiber systems using a nominal wavelength of 850nm. The electrical interface uses a 38-contact edge type connector. The optical interface uses a 12-fiber MTP/MPO connector. Features of 100G QSFP28 SR4 100m 4 channels full-duplex transceiver modules Transmission data rate up to 25Gbps per channel 4 channels 850nm VCSEL array 4 channels PIN photo detector array Hot-pluggable QSFP28 form factor Maximum link length of 70m on OM3 Multimode Fiber(MMF) and 100m on OM4 MMF Single 1X12 MPO connector receptacle Hot-pluggable electrical interface 0–70°C operating temp Low power consumption < 2.5W RoHS6 compliant (lead-free) Applications of QSFP28 100G SR4 100m 100GBASE-SR4 100G Ethernet Specifications of QSFP28 100G SR4 100m Recommended Operating EnvironmentOptical Transmitter PerformanceOptical Receiver Performance Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. Parameter Symbol Min Typical Max Unit Power Supply Voltage VCC 3.135 3.300 3.465 V Operating Case Temperature TC 0 25 70 °C Pin Descriptions of QSFP28 100G SR4 100m Pin Definition of QSFP28 100G SR4 100m Pin Symbol Name/Description 1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non-Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non-Inverted Data Input 7 GND Ground 8 ModSelL Module Select 9 ResetL Module Reset 10 Vcc Rx +3.3 V Power supply receiver 11 SCL 2-wire serial interface clock 12 SDA 2-wire serial interface data 13 GND Ground 14 Rx3p Receiver Non-Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rx1p Receiver Non-Inverted Data Output 18 Rx1n Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 22 Rx2p Receiver Non-Inverted Data Output 23 GND Ground 24 Rx4n Receiver Inverted Data Output 25 Rx4p Receiver Non-Inverted Data Output 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx +3.3 V Power supply transmitter 30 Vcc1 +3.3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non-Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Tx1p Transmitter Non-Inverted Data Input 37 Tx1n Transmitter Inverted Data Input 38 GND Ground Important Notice of QSFP28 100G SR4 100m Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by T&S before they become applicable to any particular order or contract. In accordance with the T&S policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of T&S or others. Further details are available from any T&S sales representative. T&S Communications is a professional fiber optic accessories suppliers, we provide plc splitter 1x32, qsfp28 sr4 and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 3:01 GMT
QSFP28 100G CWDM4 2K
QSFP28 100G CWDM4 2K The QSFP28 100G-CWDM4-2km module is a highly integrated 4x28G transceiver focused on reach, bandwidth, density and cost for high port-count 100G systems, and client-side 100G interfaces. It is compliant with the 100G 4WDM-10 MSA, which is based on the CWDM4 MSA version 1.1. It is interoperable with CWDM4 transceivers over a 2 km reach. Features of QSFP28 100G CWDM4 2k Reach: 2 km via SMF Link budget assumes the use of KR4 FEC by the host Uncooled CWDM DFB lasers, directly modulated Electrical interface: retimed CAUI-4 per 100G Ethernet IEEE 802.3bm Annex 83E User controllable Transmit Input Equalization and Receiver Output Amplitude MSA-compliant performance monitoring via I2C interface Fiber connector: SMF LC duplex connector Hot-pluggable 0–70°C operating temp Power dissipation < 3.5W RoHS6 compliant (lead-free) Applications of QSFP28 100G CWDM4 2k 100G CWDM4 Ethernet InfiniBand 4x EDR Specifications of QSFP28 100G CWDM4 2k Optical Transmitter PerformanceOptical Receiver PerformanceRecommended Operating Environment Parameter Symbol Min Typical Max Unit Center Wavelength Ch0 λ0 1264.5 - 1277.5 nm Ch1 λ1 1284.5 - 1297.5 nm Ch2 λ2 1304.5 - 1317.5 nm Ch3 λ3 1324.5 1337.5 nm Bit Rate per Channel B 25.78125±100ppm Gb/s Side Mode Suppression Ratio SMSR 30 - - dB Average launch power, each lane - -6.5 - 2.5 dBm Optical Modulation Amplitude (each lane) OMA -4.0 - 2.5 dBm Launch power in OMA minus TDP, each lane OMA-TDP -5.0 - - dBm Transmission & dispersion penalty, each lane TDP - - 3.0 dB RIN20 OMA - - - -130 dB/Hz Transmitter Reflectance - - - -12 dB Extinction Ratio ER 3.5 - dB Transmitter eye mask definition {X1, X2, X3, Y1, Y2, Y3} {0.31, 0.4, 0.45, 0.34, 0.38, 0.4} CWDM4 MSA Technical Specifications Rev 1.1 Total average launch power - - - 8.5 dBm Average launch power of OFF transmitter, each lane - - - -30 dBm Optical return loss tolerance - - - 20 dB Pin Descriptions of QSFP28 100G CWDM4 2k Pin Symbol Name/Description 1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non-Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non-Inverted Data Input 7 GND Ground 8 ModSelL Module Select 9 ResetL Module Reset 10 Vcc Rx +3.3 V Power supply receiver 11 SCL 2-wire serial interface clock 12 SDA 2-wire serial interface data 13 GND Ground 14 Rx3p Receiver Non-Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rx1p Receiver Non-Inverted Data Output 18 Rx1n Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 22 Rx2p Receiver Non-Inverted Data Output 23 GND Ground 24 Rx4n Receiver Inverted Data Output 25 Rx4p Receiver Non-Inverted Data Output 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx +3.3 V Power supply transmitter 30 Vcc1 +3.3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non-Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Tx1p Transmitter Non-Inverted Data Input 37 Tx1n Transmitter Inverted Data Input 38 GND Ground Important Notice of QSFP28 100G CWDM4 2k Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by T&S before they become applicable to any particular order or contract. In accordance with the T&S policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of T&S or others. Further details are available from any T&S sales representative. TS Communication is a professional fiber fiber optic products supplier, we provide qsfp28 100g,qsfp28 cwdm4, 100g qsfp28, qsfp 100g, qsfp28 and etc. Want to know qsfp28 price or more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 3:00 GMT
QSFP28 100G CWDM4 10KM
QSFP28 100G CWDM4 10KM The QSFP28 100G-CWDM4-10km module is a highly integrated 4x28G transceiver focused on reach, bandwidth, density and cost for high port-count 100G systems, and client-side 100G interfaces. It is compliant with the 100G 4WDM-10 MSA, which is based on the CWDM4 MSA version 1.1 but alters some of the specifications to extend the link reach from 2 km to 10 km. It is interoperable with CWDM4 transceivers over a 2 km reach. Features of QSFP28 100G CWDM4 10km Reach: 10 km via SMF Optical link budget: Supports 6.5 dB of link budget Link budget assumes the use of KR4 FEC by the host Uncooled CWDM DFB lasers, directly modulated Electrical interface: retimed CAUI-4 per 100G Ethernet IEEE 802.3bm Annex 83E User controllable Transmit Input Equalization and Receiver Output Amplitud MSA-compliant performance monitoring via I2C interface Fiber connector: SMF LC duplex connector Hot-pluggable 0–70°C operating temp Power dissipation < 3.5W RoHS6 compliant (lead-free) Applications of QSFP28 100G CWDM4 10km 100G CWDM4 Ethernet InfiniBand 4x EDR Specifications of QSFP28 100G CWDM4 10km Optical Transmitter PerformanceOptical Receiver PerformanceRecommended Operating Environment Parameter Symbol Min Typical Max Unit Center Wavelength Ch0 λ0 1264.5 - 1277.5 nm Ch1 λ1 1284.5 - 1297.5 nm Ch2 λ2 1304.5 - 1317.5 nm Ch3 λ3 1324.5 - 1337.5 nm Bit Rate per Channel B 25.78125±100ppm Gb/s Side Mode Suppression Ratio SMSR 30 - - dB Average launch power, each lane - -6.5 - 2.5 dBm Optical Modulation Amplitude (each lane) OMA -4.0 - 2.5 dBm Launch power in OMA minus TDP, each lane OMA-TDP -5.0 - dBm Transmission & dispersion penalty, each lane TDP - - 3.0 dB RIN20 OMA - - - -130 dB/Hz Transmitter Reflectance - - - -20 dB Extinction Ratio ER 3.5 - dB Transmitter eye mask definition {X1, X2, X3, Y1, Y2, Y3} {0.31, 0.4, 0.45, 0.34, 0.38, 0.4} 100G 4WDM-10 MSA Technical Specifications Release 1.0 Average launch power of OFF transmitter, each lane - - - -30 dBm Optical return loss tolerance - - - 20 dB Pin Descriptions of QSFP28 100G CWDM4 10km Pin Definition of QSFP28 100G CWDM4 10km Pin Symbol Name/Description 1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non-Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non-Inverted Data Input 7 GND Ground 8 ModSelL Module Select 9 ResetL Module Reset 10 Vcc Rx +3.3 V Power supply receiver 11 SCL 2-wire serial interface clock 12 SDA 2-wire serial interface data 13 GND Ground 14 Rx3p Receiver Non-Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rx1p Receiver Non-Inverted Data Output 18 Rx1n Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 22 Rx2p Receiver Non-Inverted Data Output 23 GND Ground 24 Rx4n Receiver Inverted Data Output 25 Rx4p Receiver Non-Inverted Data Output 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx +3.3 V Power supply transmitter 30 Vcc1 +3.3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non-Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Tx1p Transmitter Non-Inverted Data Input 37 Tx1n Transmitter Inverted Data Input 38 GND Ground Important Notice of QSFP28 100G CWDM4 10km Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by T&S before they become applicable to any particular order or contract. In accordance with the T&S policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of T&S or others. Further details are available from any T&S sales representative. T&S Communications is a professional fiber optic products supplier, we provide plc splitter 1x32, 1x16 plc splitter, qsfp 100 and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 2:58 GMT
PLC SPLITTER
PLC SPLITTER As a professional plc splitter manufacturer, T & S Communication produces a planar optical waveguide chip on its own and manufactures PLC splitter with self-developed PLC aligning equipment for automatic coupling. T&S PLC splitter has a good consistency and stable quality. T&S has built 10000-class and 1000- class dust-free workshops, and there are 32 sets of automatic alignment systems. T&S plc splitter factory offers premium PLC splitters of various packaging types including bare fiber type, mini type, box type, cassette type, tray type and rack-mounted type PLC splitter are available. The current monthly production capacity is 200000 PCs (1x8). Features of PLC Splitter Broadband Operation Wavelength Low Insertion loss Low PDL Compact Design Good channel-to-channel uniformity High Reliability and Stability Pass Telcordia GR-1209-Core Reliability Test Pass Telcordia GR-1221-Core Reliability Test RoHS Compliance Applications of PLC Splitter Telecommunication sector PON System FTT CATV Video Transmission Specifications of PLC Splitter Item Unit Parameter Operating Wavelength (nm) 1260 ~ 1650 1×N PLC Splitter -- 1×2 1×4 1×8 1×16 1×32 1×64 1×128 Insertion Loss MAX(P/S) (dB) 3.8/4.0 7.0/7.4 10.5/10.7 13.6/13.9 16.6/16.9 21/21.5 24/24.5 Uniformity MAX(P/S) (dB) 0.6/0.6 0.6/0.7 0.8/1.0 0.9/1.2 1.2/1.4 1.7/1.9 2.2/2.5 Return Loss MIN (dB) 55 PDL MAX(P/S) (dB) 0.15/0.25 0.15/0.25 0.2/0.25 0.2/0.3 0.25/0.3 0.25/0.35 0.4/0.45 2×N PLC Splitter -- 2×2 2×4 2×8 2×16 2×32 2×64 -- Insertion Loss MAX(P/S) (dB) 4.0/4.3 7.4/7.6 10.7/11.0 14/14.5 17.5/18 21.4/21.9 -- Uniformity MAX(P/S) (dB) 0.9/1.1 1.0/1.2 1.0/1.2 1.2/1.5 1.5/1.8 2.0/2.3 -- Return Loss MIN (dB) 55 PDL MAX(P/S) (dB) 0.25/0.3 0.25/0.3 0.25/0.3 0.3/0.35 0.3/0.35 0.35/0.4 -- Fiber Type -- ITU-T G657A1 , G657A2 Temperature Stability(-40~85℃) MAX (dB) 0.5( Typical 0.3 ) Operating Temperature (℃) -40 ~ 85 Storage Temperature (℃) -40 ~ 85 T&S Communications is a professional fiber optic products supplier, we provide plc splitter 1x4, 1x8 plc splitter and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 10/8/21 2:57 GMT
PLC CHIP
PLC CHIP As a professional plc splitter manufacturer, T&S provides a wide range of different fiber optic components at reasonable prices. Based on Planar Lightwave Circuit technologies, our PLC splitter chips can uniformly divide and guide light in the wavelength ranges from 1260nm to 1650nm. With low insertion loss (IL), low Polarization Dependent Loss (PDL) and high reliability, T&S PLC chips have been widely used in FTTx and other optical communication systems. Features of PLC Chips Low PDL Low IL Wide operating wavelength: 1260-1650nm Compact size RoHS compliance Applications of PLC Chips Among all plc splitter manufacturers, T&S chip PLC can be applied in Optical communication networks, Telecom equipment, Three-Network-Integration systems, including Signal/power distribution, Fiber-To-The-Home (FTTH), Passive Optical Network (PON). Specifications of PLC Chip Parameter Class Unit 1x2 1x4 1x8 1x16 1x32 1x64 Operating Wavelength - nm 1260 -1650 Insertion Loss P dB 3.6 6.7 9.8 13.2 16.2 19.8 PDL P dB 0.15 0.15 0.2 0.25 0.25 0.3 Uniformity P dB 0.5 0.5 0.6 0.8 1.0 1.2 Return Loss - dB - ≥55 Directivity - dB - ≥55 Operating Temperature - ℃ - -40~+85 Storage Temperature - ℃ - -40~+85 The Core Components of PLC Chips T&S Communications is a professional optic accessories suppliers, we provide plc splitter 1x32, 1x16 plc splitter and etc. Want to know more? Please contact us. Contact:
Phone: Fax: Email: T&S COMMUNICATIONS CO., LTD.
8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China Shenzhen 518118 China 8/20/21 0:54 GMT
SitemateII
Product Description Server Environment Monitoring for Small Data Center Server environment monitoring products enable you to actively keep track of the problems in your shelf, server room, information centre or anywhere else you require to safeguard essential possessions. The problems kept an eye on consist of severe temperatures, humidity, power spikes and surges, water leaks, smoke and chemical materials. With appropriate environmental monitoring, you look out to any type of problem that might have a negative impact on your mission- critical tools. These items can likewise notify you to prospective damage from human error, hacking or spying fingers. https://www.richcommdcim.com/product-s , itemateii.html Overview Server environment monitoring is specially developed and researched for small data center, it is based on IP network technology, supports UPS monitoring and server environment monitoring detection (temperature, humidity, smoke, leakage, motion, door contact, gas, etc) in one host. SitemateII provides fast interface visiting and user settings via web browser, once an abnormal alarm happens, it will rapidly give alarm notifications with email, SMS, sound light, etc, for a real sense to guarantee 7*24 hours unattended data center. Product Function Support advantage encryption protocol such as HTTP, HTTPS, SSL, SSH, SNMPV1\V2c\V3; Support telnet, supper terminal, WEB page configuration; Compatible with multi-brand and multi-type of UPS; Support to add on 20 pieces of Temp&Humid sensors via RS422/RS485 ports; With 16 digital input terminals, support to add on dry contact type detectors; With 5 digital output terminals, support to add on relay output control; Support 8 analog input signal detect; Support SNMP trap,E-mail alarm notification; Support IPV4/IPV6; Built-in optional GSM Modem, support SMS query or alarm notification; Support scheduled task(regular self-testing, switch on/off); Support history events and data record storage; Comprehensive event handle( including event record and notification); Comprehensive managing function( data logs, SNTP and task schedule); Available to work with centralized software. Technical Parameters CPU 32-bit ARM926EJ-S core 300 MHz high speed processor(CPU) RAM 64Mbyte SDRAM Flash ROM 128M byte and Flash Network Interface 10/100Mbps high speed Ethernet self adaptive Device Ports 1 RS232 asynchronous serial port; 1 RS422/485 add on port 16 Digit input terminals (0-5V TTL level); 8 Analog input terminals (0 ~ 5V linear level); 5 Digit output terminals (12VDC / 1A). Browser Support Internet Explore, Netscape or compatible browsers. SNMP MIB Support MIBII (RFC1213, RFC1315, RFC1316)RFC1628, PPC MIB Network Protocol TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP,etc. LED Indicators PW, M-PW, RUN, DEV, PPP, IPP, WEBS, SNMP, EXT, MODEM, LAN 10/ 1 00M Link/Active Input Power 220-240V Frequency 50Hz Power Consumption ≤ 12W Operating Environment Temperature:0℃~70℃ Humidity:10~85% Software Upgrade Network upgrade Other Configuration Real time system clock synchronization Languages Chinese/English, support OEM other languages. System Security Provided filtering mechanism based on IP , and system operation, control and management of the user ID and password protection. Safety Certificate CE, FCC Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China 8/20/21 0:53 GMT
SiteProII
Multi-Site UPS Monitoring System-RichComm Multi-site UPS monitoring system is a powerful monitoring host for data center power and environment, this product with one-stop high extensibility design, have dual power supply sustainable navigation, which especially suitable for power and environment monitoring of middle-small single computer rooms; Multi- site UPS monitoring system can monitor multiple smart devices (UPS, power distribution, precision air condition etc) in one device, at the same time it can extend environment monitoring like Temp&Humid, water leakage, smoke, door contact, infrared detection; SitePro support multiple alert ways like 3G, SMS, sound light, voice dialing, email etc, it is your ideal choice for data center management. Multi-site UPS monitoring system is important to ensure that your network systems are functional in the event of an interruption. Multi-site UPS monitoring system plays an indispensable component in the functioning of a company. Multi-site UPS monitoring system assists you survive a power interruption without any interruptions. An efficient multi-site UPS monitoring system software application gives you critical understandings on battery cost, performance and also sends you informs on vital. Relying on the size of the network, you can upgrade your power system to handle extended outages. The multi-site UPS monitoring system can additionally be set up to signal you when a battery needs to be changed or when a battery can not sustain the demands of a network. Multi-site UPS monitoring system are essential to keep 100% uptime for your network. The Application of Multi-site UPS monitoring system Multi-Site UPS Monitoring System Advantages Support monitoring of power equipment; Support monitoring of air condition equipment; Support monitoring of data center environment; Support link of security system; User friendly interface that is easy and con venient for use; Perfect history record; Support SNMP V2 protocol, RFC1628 MIB, XPPC MIB; Built-in WEB server to achieve HTTP access; Multiple compatibility of various brands and types of UPS, precision air condition, precision power distribution cabinet, generator, etc; Built-in rechargeable battery which can be continuous running for 8 hours when power outage; Support history events and data storage ( expansion by SD card capacity); Support to extend 8 channels of dry contact signal input(Such as smoke, water leakage, door contact, etc); Support to extend 24 channels of temperature and humidity detection and 8 general air condition infrared control; Support sound light alarm, SMS, E-mail alarm and SNMP Trap; Support multiple users authority management; Support DHCP; Support scheduled task; Support TELNET, WEB page configurations; Support network upgrade, USB upgrade. The related solution High-intergrated Monitoring Solution for Power & Environment Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China 8/20/21 0:51 GMT
Integrated monitor touch pad
Integrated monitor touch pad critical power monitor Introduction Widely used in intelligent community, bank outlets, communication operators, radio and television, medical departments and other marginal room... The integrated monitor touch pad for environment monitoring in the edge sever room uses a 9.7-inch touch screen, which can be used for work through the touch pad, and the inconvenience brought by the traditional 1U monitoring host in the edge server room and other application scenarios is abandoned.In the era of big data, it is the best choice for building a modern unguarded server room to meet customers' requirements of convenient installation, saving cabinet space, local visualization, convenient operation, necessary security and linkage operation, etc. https://www.richcommdcim.com/product-i , ntegrated-monitor-touch-pad.html Function 1. 9.7 inch LCD display screen, support touch and control function; 2. Build in front camera; 3. Abundant ports, support to monitor and connect the devices like UPS, AC, Power distribution, PDU and environment detect sensor etc ; 4. Support to detect and manage environment sensors like temp/humid sensor, door contact, smoke sensor, water leakage sensor, intrusion sensor; 5. Support linkage alarm and SMS alarm, etc; 6.Simple installation, convenient for check and management. Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China 8/20/21 0:44 GMT
NetmateLite Mini 1
NetmateLite/NetmateLite Mini Series, which will be satisfy user with a basic UPS monitoring demands. This type SNMP cards support fast installation, friendly interface visit and configuration and have been widely applied to branches UPS monitoring and control. snmp network card RichComm Function & Feature Support SNMP version V1.1; Support user authority management; Support 500 history events; With clock function; Embeded system, support web browser visit and configure; Support network upgrade; Support UPS remote control, such as UPS shutdown, self-test and reboot; Support SNMP trap, Email alarm notifications; Available to work with centralized software for centralized monitoring. https://www.richcommdcim.com/produc , t-netmatelite-mini-1.html Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China 8/20/21 0:42 GMT
NetmateLite SE
NetmateLite SE Brief Introduction NetmateLite/NetmateLite Mini Series, which will be satisfy user with a basic UPS monitoring demands. This type RichComm SNMP cards support fast installation, friendly interface visit and configuration and have been widely applied to branches UPS monitoring and control. UPS SNMP Card RichComm Function & Feature Support SNMP version V1.1; Support user authority management; Support 500 history events; With clock function; Embeded system, support web browser visit and configure; Support network upgrade; Support UPS remote control, such as UPS shutdown, self-test and reboot; Support SNMP trap, Email alarm notifications; Available to work with centralized software for centralized monitoring. https://www.richcommdcim.com/produc , t-netmatelite-se.html Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China 8/20/21 0:41 GMT
NetmateLite Mini 2
NetmateLite/NetmateLite Mini Series, which will be satisfy user with a basic UPS monitoring demands. This type SNMP cards support fast installation, friendly interface visit and configuration and have been widely applied to branches UPS monitoring and control. Function & Feature Support SNMP version V1.1; Support user authority management; Support 500 history events; With clock function; Embeded system, support web browser visit and configure; Support network upgrade; Support UPS remote control, such as UPS shutdown, self-test and reboot; Support SNMP trap, Email alarm notifications; Available to work with centralized software for centralized monitoring. https://www.richcommdcim.com/produc , t-netmatelite-mini-2.html Minimum Order: 100 Contact:
Phone: Fax: Email: RichComm System Technologies Co., Ltd
https://www.richcommdcim.com/ Guangzhou 510300 China SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
© 1996-2024 IMEXBB.com. All rights reserved.
|
|