Import-Export Bulletin Board Post an Offer to Sell

New here? Please subscribe
to post trade leads. It's FREE!

Electronics & Electrical


Home > Offers to Sell > Electronics & Electrical

Browse leads by category:
    
    
    
    
    
    
 

Summary of 11/25/24 0:20 GMT:>> Show Compact View
7/15/24 6:31 GMT
Delta Amplon N series Gen3 1-3kVA Tower Online Ups Power Supply

The Delta Amplon N series Gen3 1-3kVA tower online ups power supply system adopts an online dual converter circuit structure and a compact tower design. It can provide clean sine wave input power for IT facilities and other precision equipment, preventing work interruption, data loss, or equipment damage caused by voltage dips, spikes, harmonic distortion, and other power supply failures. -Why did I choose Delta Amplon N series Gen3 1-3kVA tower online ups power supply High availability The output power factor is as high as 0.9, which can provide more active power support for the load

Contact:
Phone:
Fax:
Email:
Chengyue
+86 193 0672 3392

Send Inquiry
Hebei Chengyue Technology Co., Ltd
3rd Floor, Ruike Instrument, No. 508 Tianning Road, Lianchi District
Baoding 071000
China
7/15/24 6:29 GMT
PHILIPS DL264 Metal led downlight 3.5W 6500K D75 BK 929003239909

Product date PHILIPS DL264 Metal led downlight 3.5W 6500K D75 BK 929003239909 Wattage:3.5W 12NC:929003239909< , br>Cut out:68-80mm Dimension:D95*H49.5mm PHILIPS Metal led downlight 3.5W 6500K D75 BK 929003239909 Exquisite craftsmanship, flexible and versatile Exquisite surface treatment highlights the low-key and restrained texture of the lamp, suitable for various decoration styles Modular design Multi-color selection One-piece modular design, simple and elegant; provide matte (white/silver/gold) three colors, easier to match different space colors Complete size and convenient application Various sizes and brightness can meet various application fields High efficiency, safety, long life and energy saving Using high-efficiency LEDs, the luminous efficacy reaches 97lm/W (6.5W), and has a long service life of 25,000 hours, saving maintenance costs

Contact:
Phone:
Fax:
Email:
Mikey Hu
15805771997
15805771997
Send Inquiry
BMT LIGHTING
ROOM 502, BUILDING A,XINYI MANSION,SHIFU ROAD
WENZHOU 325000
China
7/12/24 8:22 GMT
T4NS-4AF Safety-Door Switch K1

Limit Switch for Door Limit switch for door is used to provide feedback when a motorized door closes to a certain position to interrupt the current action or to give feedback on closing in place for other controls to ensure the safety of the process. Door limit switches are particularly useful when implementing circuit boards to simulate the closing of a door. Safety limit switch for door is available with different drive heads and contact blocks to meet all installation requirements. Welcome to contact us! Model Designations: Limit Switch for Door Item Code Description ①Conduit / connector size 1 Pg13.5   (1 conduits type) 2 G1/2   (1 conduits type) 4 M20   (1 conduits type)   (Default) ② Built-in switch A 1NC/1NO (slow-action type) B 2NC (slow-action type) ③Head Mounting Direction F Four mounting directions possible  (Front-side mounting at   shipping)/plastic D Four mounting directions possible  (Front-side mounting at   shipping)/metal Door limit switch characteristics Rating 3A 240VAC (A300) Operating speed 0.1m ~0.5m/s Contact resistance 25mΩ max. (initial).  Insulation resistance 100mΩ min. (at 500VDC) Dielectric strength AC2500V/Umip 4KV Vibration 10-55HZ,1.5mm double-amplitude Shock Mechanical: Approx. 1000m/s2 (Approx. 100G'S) Electrical: Approx. 300m/s2 (Approx. 30G'S) Ambient temperature -10℃ ~+70℃ ( With no icing) Ambient Humidity < 95% RH Life Above 300,000 Operating frequency 30 operations/min. Weight About 96g(T4N-4AF-K1) About 104G(with M20 gland) Degree of protection IP66 (initial) Operating Characteristics Key plug in force Max. 14.7N(1,500gf) Key pull out force Max. 29.42N(3,000gf) Pretravel 6±3mm Total travel (28mm) Force required to have positive Min. 58.84N(6,000gf) Positive opening travel Min. 10mm Ratings Sheet Rated voltage Noninductive Load (A) Inductive Load (A) Rated voltage Lamp Load Inductive Load Motor Load NC NO NC NO NC NO NC NO 125 VAC 5 (0.1)  1.5  1 0.7 0.5 3 2 2.5 1.5 1.3 0.8 250 VAC 3 8 VDC 5 (0.1) 2 5 4 3 14 VDC  5 (0.1)  2 4 4  3  30 VDC 4 (0.1)  2 3 3  3  125 VDC 0.4  0.05 0.4 0.4  0.05  250 VDC 0.2 0.03 0.2 0.2 0.03

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:21 GMT
TZ-8169 cats whisker lever limit Switch

Whisker Limit Switch TMAZTZ offer a wide range of whisker limit switches in different sizes. If you have any questions please contact us and we will provide you with the right limit switch for you. We have a perfect quality control system, and you can trust the quality of our products. Data Ratings Rated voltage Noninductive Load (A) Inductive Load (A) Resistance Load Lamp Load Inductive Load (A) Motor Load NC NO NC NO NC NO NC NO 125VAC 5 5 1.5 0.7 3 3 2 1 250VAC 5 5 1 0.5 3 3 1.5 0.8 8VDC 5 5 3 3 5 4 3 3 14VDC 5 5 3 3 4 4 3 3 30VDC 5 5 3 3 4 4 3 3 125VDC 0.4 0.4 250VDC 0.2 0.2 Inrush Current N.C: below  24A, N.O: below  12A NOTE:  1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC). 2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current. 3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring. Whisker limit switch characteristics ■ Double-circuit type of limit switch. ■ Compact new design approximately 1/3 the size of TMAZTZ vertical limit switches. ■ With strong zinc cast base, and reinforced plastics outer shell, High. Structure preventing oil, water and pressure. ■ Structure enables the terminal section to be fully opened for easy wiring. ■ Degree of protection: IP65 Operation speed 0.5mm-50cm/sec Operating frequency Electical: 30 operations/minute Contact resistance 25mΩ max. (initial value) Insulation resistance 100MΩ min. (below 500VDC) Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) Ambient temperature -5~+65℃ (With no icing) Humidity <95% RH Weight About 130 to 190g Degree of protection IP65 Electrical Life Above 500000 Operating Characteristics Operating Characteristics  Model TZ-8104 TZ-8107 TZ-8108 TZ-8111 TZ-8112 TZ-8122 TZ-8166 TZ-8167 TZ-8168 TZ-8169 Operating force OF    (Max) 5.88N 5.88N 7.84N 9.8N 9.8N 9.8N 0.88N 0.88N 0.88N 0.88N Release force RF    (Min) 0.49N 0.69N 0.49N 2.94N 2.94N 2.94N 一 一 一 一 Pre-travel PT    (Max) 20° 20° 20° 1.5mm 1.5mm 1.5mm 30mm 30mm 30mm 30mm Over-travel OT    (Min) 75° 75° 75° 4mm 4mm 4mm 一 一 一 一 Movement differential MD   (Max) 10° 10° 10° 1.2mm 1.2mm 1.2mm 一 一 一 一 Total travel TT    (Min) 95° 95° 95° 5.5mm 5.5mm 5.5mm 一 一 一 一 Operational position OP 一 一 一 26±0.8mm 一 一 一 一

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:20 GMT
V-15-1C25 basic plunger model Micro Switch

■ High accuracy of action position; ■ Good shock resistance, maximum 1000m/s2; ■ High-strength shell, when mounting, the plastic shell can withstand torsional moment of 6kgf.cm without break. Ratings Item  nominal voltage Noninductive Load (A) Inductive Load (A) Inrush Current(A) Spec. Resistance Load Lamp Load Inductive Load Motor Load NC NO NC NO NC NO NC NO NC NO 16A 250VAC 16 2 10 3 40max. 8VDC 16 4 10 6 30VDC 10 4 10 4 125VDC 0.6 0.1 0.6 0.1 250VDC 0.3 0.05 0.3 0.05 Characteristics Operation speed 0.1mm~1m/s( Button type) Operating frequency Electrical:20 operations/min Insulation resistance 100mΩ above(at 500VDC) Contact resistance 15mΩmax. (initial value) Withstand voltage Non-continuous terminals 1,000VAC, 50/60Hz  Continue1min current-carrying and non-current-carrying metal parts,  Between terminal and earthing 2,000VAC, 50/60Hz  Continue1min Vibration Misoperation 10 to 55Hz,1.5mm pairs swing Shock Misoperation Max 300m/S2(about 100G) Temperature -10~+65℃(no ice) Humidity Under 85%RH(+5~+35℃) Weight Approx 6.2g (button type) Electrical life Above300000 Operating Characteristics Operating Characteristics Model V-15 V-151 V-152 V-153 V-154 V-155 V-156 Operating force OF  (Max) 1.96N 1.96N 1.23N 0.69N 1.23N 2.35N 1.23N Release force RF  (Min) 0.49N 0.49N 0.14N 0.06N 0.14N 0.49N 0.14N Pre-travel PT  (Max) 1.2mm 1.6mm 4.0mm 9.0mm 4.0mm 1.6mm 4.0mm Over-travel OT  (Min) 1.0mm 0.8mm 1.6mm 2.0mm 1.6mm 0.8mm 1.6mm Movement differential MD (Max) 0.4mm 0.6mm 1.5mm 2.8mm 1.5mm 0.6mm 1.5mm Operational position OP 14.7±0.4mm 15.2±0.5mm 15.2±1.2mm 15.2+2.6mm 15.2-3.2mm 18.7±1.2mm 20.7±0.6mm 20.7±1.2mm

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:20 GMT
T4N-4131 Safety Limit Switch

■ Forced open action device(NC contacts only), it can disconnect the contact when the contact has fusing and other failures. ■ Standardized gold-clad contacts provide high contact reliability, Can be used with both standard loads and microloads. ■ Strengthened top seal structure improves the sealing performance. ■ Built-in contact holder has fast-action type: 1NC/1NO; Slow-action: 1NC /1NO and 2NC. Characteristics Protection level*1 IP66 Life*2 Electrical More than 300,000 times (AC250V 10A, resistive load) Electrical More than 500,000 times (AC250V 3A, resistive load) *3 Operating speed 1 ~ 500mm/s(T4N-4120) Operating frequency Max. 30 times/min Contact resistance 25 mΩ or less Minimum working load *4 1mA resistive load below DC5V (N standard reference value) Rated insulation voltage (Ui) 300V Electric shock proof protection grade Class II (double insulated) Pollution degree (environmental conditions) Pollution degree 3 (EN60947-5- 1) Withstand voltage (EN60947-5-1) Between homopolar terminals: 2.5kV Between heteropolar terminals: 2.5kV Between terminals and uncharged metal parts: 6kV insulation resistance Above 100MΩ Contact gap Minimum 2×0.5mm quick-action type, Minimum 2×2mm slow-action type Vibration Malfunction 10 ~ 55Hz 0.75mm single amplitude Impact Duration 1,000m/s2 Malfunction 300m/s2 Ambient temperature -20 ~ +70℃ (No ice or dew) Ambient humidity Less than 95% RH Weight About 73g (T4N-4120) About 82g (T4N-4120 with gland) Note1:The above values are initial values. Note2:Once the contact is connected to a standard load, it can not be used to connect a smaller load. If so, the contact may result in rough surface, thus losing contact reliability. ①The protection level is gotten based on test method of (EN60947-5-1). Please make sure its sealing under actual environmental conditions before use. The switch box has dust and oil resistance structure, but it should be used in places without dust, oil and chemicals. Otherwise it may lead to premature wear, damage or malfunction. ②The durability is for ambient temperature of 5℃ ~ 35℃ and humidity of 40% to 70% RH. ③For additional details, please contact us. ④When the ambient temperature is above 35℃ , more than 2 circuits 3A 250VAC loads are prohibited. ⑤The values will vary with different switching frequency, environmental conditions, reliability level and other factors. Please confirm on the actual load in advance. The mechanical life of deadman lever type is more than 10,000,000 times. Safety Limit Switch Model Designations Item Code Description ① Conduit / connector size 1 Pg13.5 (1 conduit type) 2 G1/2 (1 conduit type) 4 M20 (1 conduit type) 5 Pg13.5 (2 conduits type) 6 G1/2 (2 conduits type) 8 M20 (2 conduits type) ② Built-in switch 1 1NC/1NO (quick-action type) 2 2NC (quick-action type) A 1NC/1NO (slow-action type) B 2NC (slow-action type) ③Head and driving rod 20 Roller lever (resin lever, resin ball) 22 Roller lever (metal lever, resin ball) 25 Roller lever (metal lever, metal resin ball) 2G Adjustable roller lever, Form Lock (metal lever, resin ball) 2H Adjustable roller lever, Form Lock (metal lever, rubber ball) 2M Adjustable roller lever, Form Lock (metal lever, metal resin ball) 31 Top plunger type 32 Top plunger ball type 62 Unilateral cantilever ball type (horizontal) 72 Unilateral cantilever ball type (vertical) 80 Whisker type 87 Plastic stick type

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:19 GMT
TSA-001 sealed plunger actuator Limit Switch

■ Stainless steel idler wheel, punch and spring; ■ Selective M18x1.5 cable gland. Ratings Rated voltage Noninductive Load (A) Inductive Load (A) Resistance Load Lamp Load Inductive Load (A) Motor Load NC NO NC NO NC NO NC NO 125VAC 5 5 1.5 0.7 3 3 2 1 250VAC 5 5 1 0.5 3 3 1.5 0.8 8VDC 5 5 3 3 5 4 3 3 14VDC 5 5 3 3 4 4 3 3 30VDC 5 5 3 3 4 4 3 3 125VDC 0.4 0.4 250VDC 0.2 0.2 Inrush Current N.C: below  24A, N.O: below  12A NOTE:  1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC). 2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current. 3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring. Characteristics Operation speed 0.5mm-50cm/sec Operating frequency Electical: 30 operations/minute Contact resistance 25mΩ max. (initial value) Insulation resistance 100MΩ min. (below 500VDC) Dielectric Strength 1000VAC, 50/60 Hz for 1 minute between terminals of the same polarity 1500VAC, 50/60 Hz for 1 minute between current-carrying and non- current-carrying metal parts 1500VAC, 50/60 Hz for 1 minute between each terminal and ground Vibration 10-55Hz,1.5mm double amplitude Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) Ambient Temperature  -10~+65℃ (With no icing) Humidity <95% RH Weight About 195 to 246g Electrical Life Above 500000 Degree of protection IP65 Operating Characteristics Operating Characteristics Model TSA-001 TSA-003 TSA-012 TSA-021 TSA-041 TSA-031 TSA-051 TSA-061 TSA-071 TSA-081 Operating force OF  (Max) 7.84N 7.84N 7.84N 3.92N 3.92N 3.92N 3.92N 1.47N 1.47N 1.47N Release force RF  (Min) 3.92N 3.92N 3.92N 0.98N 0.98N 0.98N 0.98N 0.49N 0.49N 0.49N Pre-travel PT  (Max) 1.8mm 1.8mm 1.8mm 20° 20° 20° 20° 30mm 30mm 30mm Tripping position TP±10% 2.0mm 2.0mm 2.0mm 22.5° 22.5° 22.5° 22.5° 22.5° 22.5° 22.5° Movement differential MD (Max) 1.2mm 1.2mm 1.2mm 10° 10° 10° 10° 14° 14° 14° Over travel OT  (Min) 4.0mm 4.0mm 4.0mm 75° 75° 75° 75° 20mm 20mm 20mm Total travel TT  (Min) 5.8mm 5.8mm 5.8mm 95° 95° 95° 95° 50mm 50mm 50mm Rotary indexing 22.5° 22.5° 22.5° 22.5° visit our website: https://www.chinalimitswitch.com/limit-switch/

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:18 GMT
TZ-8104 roller lever actuator Limit Switch

■ Double-circuit type of limit switch. ■ Compact new design approximately 1/3 the size of TMAZTZ vertical limit switches. ■ With strong zinc cast base, and reinforced plastics outer shell, High. Structure preventing oil, water and pressure. ■ Structure enables the terminal section to be fully opened for easy wiring. ■ Degree of protection: IP65 ■ Aslo includes stainless steel roller model TZ-8 Limit Switches TZ-8 limit switch in the specific production and manufacture, the limit switch is installed in a pre-arranged part, when the control module installed on the production of molecular thermal motion components collides with the limit switch, the contact point posture of the limit switch completes the conversion of the power supply circuit. Therefore, the limit switch is a kind of household appliance that converts the power supply circuit according to the stroke arrangement part of the fitness exercise component, and its basic principle of efficacy is similar to that of the button. Ratings Rated voltage Noninductive Load (A) Inductive Load (A) Resistance Load Lamp Load Inductive Load (A) Motor Load NC NO NC NO NC NO NC NO 125VAC 5 5 1.5 0.7 3 3 2 1 250VAC 5 5 1 0.5 3 3 1.5 0.8 8VDC 5 5 3 3 5 4 3 3 14VDC 5 5 3 3 4 4 3 3 30VDC 5 5 3 3 4 4 3 3 125VDC 0.4 0.4 250VDC 0.2 0.2 Inrush Current N.C: below  24A, N.O: below  12A NOTE:  1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC). 2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current. 3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring. Characteristics Operation speed 0.5mm-50cm/sec Operating frequency Electical: 30 operations/minute Contact resistance 25mΩ max. (initial value) Insulation resistance 100mΩ min. (below 500VDC) Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) Ambient temperature -5~+65℃ (With no icing) Humidity <95% RH Weight About 130 to 190g Degree of protection IP65 Electrical Life Above 500000 Operating Characteristics Operating Characteristics  Model TZ-8104 TZ-8107 TZ-8108 TZ-8111 TZ-8112 TZ-8122 TZ-8166 TZ-8167 TZ-8168 TZ-8169 Operating force OF   (Max) 5.88N 5.88N 7.84N 9.8N 9.8N 9.8N 0.88N 0.88N 0.88N 0.88N Release force RF   (Min) 0.49N 0.69N 0.49N 2.94N 2.94N 2.94N 一 一 一 一 Pre-travel PT   (Max) 20° 20° 20° 1.5mm 1.5mm 1.5mm 30mm 30mm 30mm 30mm Over-travel OT   (Min) 75° 75° 75° 4mm 4mm 4mm 一 一 一 一 Movement differential MD  (Max) 10° 10° 10° 1.2mm 1.2mm 1.2mm 一 一 一 一 Total travel TT   (Min) 95° 95° 95° 5.5mm 5.5mm 5.5mm 一 一 一 一 Operational position OP 一 一 一 26±0.8mm 一 一 一 一

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 8:17 GMT
TZ-8108 adjustable roller lever Limit Switch

TZ-8108 adjustable roller lever Limit Switch ■ Double-circuit type of limit switch. ■ Compact new design approximately 1/3 the size of TMAZTZ vertical limit switches. ■ With strong zinc cast base, and reinforced plastics outer shell. ■ Structure enables the terminal section to be fully opened for easy wiring. ■ Degree of protection: IP65 ■ Aslo includes stainless steel roller model Voltage Ratings Rated voltage Noninductive Load (A) Inductive Load (A) Resistance Load Lamp Load Inductive Load (A) Motor Load NC NO NC NO NC NO NC NO 125VAC 5 5 1.5 0.7 3 3 2 1 250VAC 5 5 1 0.5 3 3 1.5 0.8 8VDC 5 5 3 3 5 4 3 3 14VDC 5 5 3 3 4 4 3 3 30VDC 5 5 3 3 4 4 3 3 125VDC 0.4 0.4 250VDC 0.2 0.2 Inrush Current N.C: below  24A, N.O: below  12A NOTE:  1. Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC). 2. Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current. 3. Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring. TZ 8108 Limit Switch Characteristics High rigidity structure, made of high-strength plastic and aluminum; Cast (head and lid clinging to the box); Small size, waterproof and oilproof structure; Built-in micro switch, double spring mechanism, longer mechanical life; Easy wiring circuit opening design. Operation speed 0.5mm-50cm/sec Operating frequency Electical: 30 operations/minute Contact resistance 25mΩ max. (initial value) Insulation resistance 100mΩ min. (below 500VDC) Shock Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) Ambient temperature -5~+65℃ (With no icing) Humidity <95% RH Weight About 130 to 190g Degree of protection IP65 Electrical Life Above 500000 Limit Switch TZ-8108 Operating Characteristics Operating Characteristics  Model TZ-8104 TZ-8107 TZ-8108 TZ-8111 TZ-8112 TZ-8122 TZ-8166 TZ-8167 TZ-8168 TZ-8169 Operating force OF   (Max) 5.88N 5.88N 7.84N 9.8N 9.8N 9.8N 0.88N 0.88N 0.88N 0.88N Release force RF   (Min) 0.49N 0.69N 0.49N 2.94N 2.94N 2.94N 一 一 一 一 Pre-travel PT   (Max) 20° 20° 20° 1.5mm 1.5mm 1.5mm 30mm 30mm 30mm 30mm Over-travel OT   (Min) 75° 75° 75° 4mm 4mm 4mm 一 一 一 一 Movement differential MD  (Max) 10° 10° 10° 1.2mm 1.2mm 1.2mm 一 一 一 一 Total travel TT   (Min) 95° 95° 95° 5.5mm 5.5mm 5.5mm 一 一 一 一 Operational position OP 一 一 一 26±0.8mm 一 一 一 一 If you do not have the limit switch you are looking for, please contact us and we will design and manufacture your own limit switch, such as rollers or plungers, etc., as well as wiring methods can be customized according to your requirements.

Contact:
Phone:
Fax:
Email:
Bill Lin
057762962298

Send Inquiry
Yueqing Yongde Electric Co., Ltd.
Lingmen Village, Beibaixiang Town, Yueqing City, Zhejiang Province
Yueqing 325603
China
7/12/24 1:08 GMT
28kW Wheeled Generator, 50Hz, Gasoline Fueled, Water Cooling

Introducing our 28kW Wheeled Generator, crafted by a trusted manufacturer for reliable power on the move. Operates at 50Hz, fueled by gasoline, and equipped with a self-excited AVR, 100% copper coil, and a brushless alternator. The water- cooled system and robust 4-cylinder, 4-stroke engine ensure efficient and stable performance. With wheels for enhanced mobility, this generator is a versatile and dependable solution for various applications requiring on-the-go power.If you would like to obtain more information, please visit our website...

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Genset
86-592-5819200

Send Inquiry
China Genset Generator Manufacturers Co., Ltd.
NO.93, East Hubin Road, Xiamen, Fujian, China
Xiamen 361000
China
7/12/24 1:07 GMT
640kW Container Generator, Perkins Engine, 50Hz, Water Cooled

Introducing our Containerized Perkins Powered Diesel Generator, delivering a prime power of 640kW (800kVA) at a frequency of 50Hz. Equipped with a reliable 4- stroke, 6-cylinder engine, this generator ensures efficient performance. Trust in our generator for reliable and robust power supply in various applications.If you would like to obtain more information, please visit our website...

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Genset
86-592-5819200

Send Inquiry
China Genset Generator Manufacturers Co., Ltd.
NO.93, East Hubin Road, Xiamen, Fujian, China
Xiamen 361000
China
7/12/24 1:06 GMT
64kW 80kVA Silent Generator, Perkins 1104A-44TG2, 4 Cylinder

Introducing our silent type diesel generator, supplying 64 kW (80 kVA) of power. Powered by a 4-stroke, 4-cylinder Perkins 1104A-44TG2 engine and equipped with a Leroy Somer TAL-A44-C alternator, this generator operates at a noise level of 70 dBA at 7 meters. Trust in our generator for quiet and reliable power supply in various settings.If you would like to obtain more information, please visit our website...

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Genset
86-592-5819200

Send Inquiry
China Genset Generator Manufacturers Co., Ltd.
NO.93, East Hubin Road, Xiamen, Fujian, China
Xiamen 361000
China
7/12/24 1:05 GMT
1000kW Natural Gas Generator, Perkins 4016-61TRS2, 4 Stroke

Presenting a top-of-the-line 4 Stroke Natural Gas Generator crafted to deliver remarkable performance, boasting a rated power of 1000kW and 1250kVA. This powerhouse is driven by the formidable Perkins 4016-61TRS2 Engine, featuring 16 cylinders of raw energy. Paired with the reliable Stamford S6L1D-G4 Alternator, this generator promises unmatched reliability and efficiency for your most demanding power needs.If you would like to obtain more information, please visit our website...

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Genset
86-592-5819200

Send Inquiry
China Genset Generator Manufacturers Co., Ltd.
NO.93, East Hubin Road, Xiamen, Fujian, China
Xiamen 361000
China
7/12/24 1:03 GMT
20kW Diesel Generator, Perkins 404D-22TG, 3 Phase, 4 Cylinder

Introducing our versatile 3-phase diesel generator, featuring a Perkins 404D-22TG engine, offering a prime power of 20 kW and 25 kVA. With its robust 4-cylinder, 4-stroke design and Stamford PI144E alternator, this generator provides reliable performance for various applications. Designed for efficiency and durability, it's an ideal choice for your power generation needs.If you would like to obtain more information, please visit our website...

Minimum Order: 1 bags

Contact:
Phone:
Fax:
Email:
Genset
86-592-5819200

Send Inquiry
China Genset Generator Manufacturers Co., Ltd.
NO.93, East Hubin Road, Xiamen, Fujian, China
Xiamen 361000
China
7/9/24 9:08 GMT
BMK Powder 5449–12–7 CAS 20320–59–6 BMK 24 hours germany pick up

how to buy 5449-12-7 BMK Powder, Name 2-methyl-3-phenyl-oxirane-2-carboxylic acid where to buy5449-12-7 BMK Powder, Number 5449-12-7 sell 5449-12-7 BMK Powder, Molecular Weight 201.17400 buy 5449-12-7 BMK Powder, Density 1.28g/cm3 5449-12-7 BMK Powder, Boiling Point 334.3ºC at 760 mmHg 5449-12-7 BMK Powder, Molecular Formula C10H10NaO3+ We are here provide the best qualitsy products,100% safety gurantee. We are a real and honest manufacturer. We guarantee you safety and fast delivery. We have the lowest factory price. We can negotiable for the big quantity. We provide big discount for regular customers. Can pick up from our German and Australian warehouse.a whatsapp/ telegram/Signal: +8616632975433 Threema: TP3K8TRD Key words: Bmkpowder, bmkoil,5449-12-7, cas 5449-12-7, Bmk Glycidic Acid, BMK powder,order 5449-12-7, sell 5449-12-7, buy 5449-12-7, buy bmk powder, 20320-59-6, sell bmk powder, bmk acid powder, cas 20320-59-6, Benzyl Methyl Ketone oil, Bmk Glycidic,

Contact:
Phone:
Fax:
Email:
jennie
16632975433

Send Inquiry
nanjin saibainuokeji
zhongnan road
Aaryaad 70
China


SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
Result Page:   << Previous   |   55  |   56  |   57  |   58  |   59  |   60  |   61  |   62  |   63  |   64  |   65  |   Next >>

Post an Offer to Sell
Home - Offers to Buy - Business Opportunities - Company Profiles

© 1996-2024 IMEXBB.com. All rights reserved.

IMEXBB.com