Industrial Control Line AI/AO Analog signal RS485 Protector
Industrial Control Line AI/AO Analog signal RS485 Protector The control signal lightning protector is designed to protect the control line system to protect the electrical and electronic equipment's signal line from the impact of the lightning electromagnetic pulse, induced over-voltage, transient operation, and resonance overvoltage. The interface form of the product is crimp type, which protects 1-4 lines, and can be used in industrial control fields with different voltage specifications of 6-48V.
Control line protector is designed for control line system to protect electrical and electronic equipment's signal line from the impact of lightning electromagnetic pulse, induced over voltage, transient operation and resonance over voltage. The control line surge arrester lan can be used in RS232, LAN, MODEM BUS, etc.
Application of SPD for Control Signal System V.1, X.27, RS485, RS422, RS232 protector.
LAN, CAN, V.24/RS232-C, MODEM surgeĀ protector bus.
TOKEN-RING, INDUSTRIAL BUS.
Suitable for the signal's transmission rate protection under the same voltage and same specifications.
Analog signal lightning arrester.
Protect power supply and control line for camera.
Loss prevention system device; Security system; Security integration.
IASP; VSCS; ESA; ACS; exit-inlet control system; exit-inlet control system.
Technical Parameters of SPD for Control Signal System
Model D05Y2(-A) D05Y4 D12Y2(-A) D12Y4 D24Y4 D36Y2(-A) Lightning projection zone(LPZ) 2 Standards Compliance IEC61000, EN60950 According to IEC61643 III According to DIN VDE6075 Part6(Draft 11.89) A1, A2 D Max continuous operating voltage Uc 5V 12V 24V 36V Nominal discharge current (8/20s) In 3K Max discharge current Imax (8/21s) Imax 5KA Limiting Voltage(10/700s) 20V 40V 100V 120V Cut-off Frequency fG 20MHz Response time tA (LN / N-PE) 1ns Protection port 2 4 2 4 4 2 Mounting Be Installed between protected equipment and signal line Max connecting line diameter 1.5mm2 Recommend connecting line diameter 1mm2 Transmission standards 10Mbps Dimension Regular type: 85*25*25mm DIN rail type: 90*14*65mm Interface form Compression plug IP code (IEC EN 60529) IP20 Largest terminal installation torque 0.6-0.8 N.m Material/color Aluminum/Blue Insertion loss 5dB Working conditions Temperature: -40 to 85 Relative humidity
Features of SPD for Control Signal System Low insertion loss, fast response
Low limiting voltage
Precise limiting voltage
Strong discharge current
Crimping
If you want to know more about lan surge protector , please contact us.
As one of surge arrester manufacturers, we will provide more high quality products for customers, if you have needs, please leave us a message.