Import-Export Bulletin Board Lepu Medical Technology(Beijing)Co.,Ltd Logo

Home > Offers to Sell > Health & Beauty > Medical Supplies > Other Medical Supplies

Contact: lepumedical
Company: Lepu Medical Technology(Beijing)Co.,Ltd
No.37 Chaoqian Road Changping District, Beijing, China
Beijing 102200
China
E-Mail: Send Inquiry Member for over 2 years
Date/Time:  10/25/21 1:45 GMT
 

GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System

To develop Lepu Medical into one of the largest cardiovascular products
manufacturers and on the platforms of medical device, medicine, healthcare
products, healthcare service and new medical mode.

GuReater® CoCr Stent Sirolimus-eluting Coronary Stent System Details
Product Description
GuReater® is a CoCr drug-eluting stent covered with stent sirolimus. Its 75
μm CoCr strut provides super flexibility and crossability to ensure the
great compliance after implantation.

Product Features
CoCr stent has great radiopacity and biocompatibility.
75μm ultrathin strut guarantees the excellent flexibility of the stent
during delivery, and helps with better endothelialization.
Extremely low recoil ratio of 3.4% for CoCr stent ensures better stent
apposition to reduce the risk of thrombosis.
PLGA biodegradable polymer coating provides precise drug releasing control
and scientific degradation period.
75 μm ultrathin strut thickness and unique strut structure guarantee the
excellent compliance of the stent during delivery.
CoCr stent has great radiopacity, biocompatibility, and provides excellent
balance between radial strength and flexibility.
MRI compatible

Product Ranges
Ø 2.5 - 4.0 mm
12 - 36 mm multi stent lengths

Specifications
Technical Parameters
Stent Material L605 CoCr Alloy
Strut Design Open cell
Metal to Artery Ratio 15%
Recoil 3.40%
Shortening < 1%
Strut Thickness 75 μm
Crossing Profile 0.035″(0.90mm)

Ordering Information
Stent Stent Length (mm)
Diameter
(mm) 12 15 18 21 24 29 33 36
2.5 LPRPC2512 LPRPC2515 LPRPC2518 LPRPC2521
LPRPC2524 LPRPC2529 LPRPC2533 LPRPC2536
2.75 LPRPC2712 LPRPC2715 LPRPC2718 LPRPC2721
LPRPC2724 LPRPC2729 LPRPC2733 LPRPC2736
3 LPRPC3012 LPRPC3015 LPRPC3018 LPRPC3021
LPRPC3024 LPRPC3029 LPRPC3033 LPRPC3036
3.5 LPRPC3512 LPRPC3515 LPRPC3518 LPRPC3521
LPRPC 3524 LPRPC3529 LPRPC3533 LPRPC3536
4 LPRPC4012 LPRPC4015 LPRPC4018 LPRPC4021
LPRPC4024 LPRPC4029 LPRPC4033 LPRPC4036

Please contact local sales for details before placing order.
GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System
Enlarge Click to Enlarge
SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)