Import-Export Bulletin Board Jiancheng Electronics Co., Ltd. Logo

Home > Offers to Sell > Electronics & Electrical > Generators > Generator Parts & Accessories

Contact: Han Lee
Company: Jiancheng Electronics Co., Ltd.
Room 601, No. 169, Tianhui road, ACC Square, H-Tech Zone
Chengdu 621000
China
Phone: 8618281509557
E-Mail: Send Inquiry Member for over 2 years
Date/Time:  7/21/21 1:38 GMT
 

Data Center data center hardware

Data Center data center hardware internet data center idc micro module
Data Center manufacturer

windstream data center Description
The Airtight Channel System
The Characteristics of System
Channel system controls the air transport path, provides high density of
refrigeration guarantee;
Significantly improve the cool air utilization of the air-conditioning system,
reduce consumption of data room;
Cold Aisle is modular design so that can achieve quick connect;
Intelligent control host can connect with fire extinguishing system,and upload
the data of environment;
Using the design of fire-proof material automatic monitoring and warning
improve security.

The Frame of Cool Channel Airtight System
By obturating cool air entrance in the front of cabinet, the cool channel
airtight system can put the cool air made by precision air-conditioning
transport to the front-end of IT device as design plan. In order to improve the
utilization of heat and cool air and realize the effect of energy saving and
emission reduction by adding a flow sealing plate to isolate heat and cool air
inside of the cabinet. The structure include channel activity containment door,
channel airflow containment door, airflow control units of floor and cabinet.

The Frame of Heat Channel Airtight System
The heat channel airtight system, by concentrating heat air in the control
areas exhausted behind the cabinet, and unify reflow to precision air-
conditioning return air grille so that heat air can not spread in internal
cabinet during the whole process. The cold source air inlet of the cabinet is
not disturbed by it, and there is no energy loss of the product, which improves
the efficiency of air conditioner.

Jiancheng-Data Center Rack Design Structure Characteristics
Meet the standards of ANSI/EIA-310-D, GB/T15295-94, GB/T3047.2-92, IEC61587-2-
2011; Compatible standard of ETSI;
The frame of whole cabinet made by sheet metal; static load1300kg; dynamic load
1000kg;
Complete machine delivery, or spare parts delivery; easily assemble and reduce
transportation and storage space;
The width of the cabinet is standard 600mm and 800mm; depth and height can be
arbitrary configuration;
The front door can configure hexagonal wire mesh door whose ventilation rate
can achieve 75%, or can configure glass door; both of them compatible the
opening methods of left way and right way so that convenient to adjust the
direct of opening based on site needs of customers;
The back door can configure double mesh door to save the space.of cabinet
installation;
Side plate use double open of up and down so that convenient disassembly and
installation;
Each parts of the cabinet inside can be grounded;
Installation vertical post print the installation indicate position so that the
user can install convenient;
The cabinet configure the universal wheels and stand bar so that it can be
moved and fixed convenient;
Flexible cabinet pick the mountings; up cabling and down cabing is compatible.
 
Material/Superficial Treatment
Electrostatic spraying.

600, 800 Arc Mesh Cabinet
Width of 600 and 800 combination cabinet, the front door's material is mesh
ventilation material, depth between 600 to 1200 can be configured, height
between 24U to 47U can be configured, the color have computer gray and black.
The way of exhausting air: enter from front and exit from back.

600, 800 glass cabinet
Width of 600 and 800 combination cabinet, the front door’s material is glass,
depth between 600 to 1200 can be configured, height between 24U to 47U can be
configured, the color is computer gray and black.
The way of exhausting air: enter from bottom and exit from back.

600, 800 Plate Mesh Cabinet
Width of 600 and 800 combination cabinet, the front door's material is plate
mesh, depth between 600 to 1200 can be configured, height between 24U to 47U
can be configured, the color is gray and black.
The way of exhausting air: enter from front and exit from back.

Our data center hardware is data center rack layout for windstream, We can
customize IDC micro module according to customer needs and provide
refrigeration guarantee.

UPS power supply, several kinds of ups electrical system are sold. We provide
UPS power supply program support. Jiancheng is also a charging pile supplier
about integrating technology, after-sales, installation and maintenance.

https://www.jch-electronics.co , m/product-data-center-hardware.html
Data Center    data center hardware
Enlarge Click to Enlarge
SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
Report Abuse

Post an Offer to Sell

© 1996-2010 IMEXBB.com. All rights reserved.

IMEXBB.com