Import-Export Bulletin Board Zhejiang Aoshuai Refrigeration Co., Ltd Logo

Home > Offers to Sell > Environment & Recycling > Waste Management > Recycling Machinery

Contact: ctauvc
Company: Zhejiang Aoshuai Refrigeration Co., Ltd
3-1-3, Cantonment Exchange, 698, Jalan Sultan Azlan Shah (Jalan
shaoxing 312300
China
Phone: 057582331987
E-Mail: Send Inquiry Member for over 2 years
Date/Time:  12/14/21 2:54 GMT
 

Cooling Tower Sprinkler Head

The cooling tower sprinkler head is a special water distributor for small and
medium-sized round counter flow cooling tower. Through the small holes on the
water distribution pipe, the water is evenly spread on the filler, increasing
the water vapor contact interface, so that cooling tower sprinkler head parts
and takes away heat, thus reducing the water temperature.

Material of Cooling Tower Sprinkler Head
ABS, nylon, nylon copper, aluminum alloy.

Maintenance Points of Sprinkler Head in Cooling Tower
a. When installing the sprinkler for cooling tower, check outside the tower
first, and arrange the sprinkler head and water distribution pipe of sprinkler
head cooling tower. Check whether the bearing and diameter of sprinkler head of
cooling tower are consistent with the diameter of water inlet of cooling tower.

b. Clean the water inlet of cooling tower and grind it. (here are the necessary
steps for cooling tower maintenance)

c. Lift the sprinkler head of the cooling tower into the tower and then place
the sprinkler head on the water inlet smoothly. Here we should pay attention to
the construction of the cooling tower filler to lay wood, so as not to damage
the filler. Then tighten the water inlet and sprinkler head with nuts,
diagonally. Prevent the sprinkler head from imbalance.

d. Find the level ruler you brought in advance and put it on the sprinkler
head. Adjust the sprinkler head according to the level to the balance position.

e. Then install the water distribution pipe in turn, and the water distribution
pipe shall present a 30°angle with the packing plane of the cooling tower. And
the spray direction of each water distribution pipe should be consistent.

f. After the installation, manually wave the water distribution pipe. Check
whether the rotation is normal and whether there is friction on the tower body.

Characteristics of Sprinkler Head in Cooling Tower
a. Durable
The cooling tower sprinkler head is corrosion resistant, high-strength, water
and gas resistant, beautiful and durable, and it does not need maintenance for
3 years.

b. Low outlet pressure
The working pressure at the outlet of the nozzle is only 0.6mh2o, which has a
large pressure adaptation range, low cost and stable quality.

c. Safe and reliable
If the nozzle of the cooling tower is damaged for various reasons, the cooling
tower sprinkler head can be replaced in time, shorten the time of cooling tower
sprinkler system recovery and alert state, so as to be safe and reliable in
use.

d. Anti clogging
The spray head of cooling tower is easy to clean, makes the water distribution
even and not easy to block, which is conducive to improve the cooling effect of
cooling tower.

e. Easy to maintain

The nozzle of the cooling tower is very small, which is easy to block, which
causes uneven water distribution and convenient maintenance.

Our cooling tower company provides cooling tower filling, drift eliminator,
fan, motor, gearbox, belt reducer, spray nozzle, sprinkler head, float ball,
air inlet louvers, etc... Whatever cooling tower parts you need, you will find
them in our cooling towers LLC AUVC.