Import-Export Bulletin Board  

Home > Offers to Sell > Health & Beauty > Medical Equipment

Contact: Mrs. Lina
Company: Shanghai Lina Medical Device Technology Co., Ltd.
Building C, No. 888 Huanhu West Second Road, Lin'gang New Area, China (Shanghai) Pilot Free Trade Zone
shanghai 200000
China
Phone: 86-138-15032325
Fax: 86-138-15032325
E-Mail: Send Inquiry Member for over 1 year
Date/Time:  7/25/23 10:02 GMT
 

Blood Lipid Analyzer PFS-30 (With Bluetooth); PFS-30A

Blood Lipid Analyzer PFS-30 (with Bluetooth); PFS-30A: A Comprehensive Analysis
of System Performance Characteristics and Technical Parameters



When it comes to accurate and reliable blood lipid analysis, the Blood Lipid
Analyzer PFS-30 (with Bluetooth) and its counterpart, the PFS-30A, stand out as
exceptional devices. These analyzers offer a wide range of features and
specifications designed to provide accurate results and convenient data
management. In this article, we will delve into the system's performance
characteristics, technical parameters, and additional benefits it brings to the
table.

System Performance Characteristics
1.1 Accuracy

The accuracy of the Blood Lipid Analyzer is established by comparing its
results with those of an automatic biochemical analyzer in parallel testing.
The analyzer adheres to strict allowable deviation limits for various
parameters. Here are the specific accuracy requirements:

Total Cholesterol (TC): The detection range for TC is 2.59 to 12.93 mmol/L (100
to 500 mg/dL). The correlation coefficient (r value) should be equal to or
greater than 0.95.
Triglyceride (TG): The detection range for TG is 0.51 to 7.34 mmol/L (45 to 650
mg/dL). The r value should be equal to or greater than 0.95.
High-density Lipoprotein Cholesterol (HDL): The detection range for HDL is 0.39
to 2.59 mmol/L (15 to 100 mg/dL). The r value should be equal to or greater
than 0.95.
1.2 Precision

The Blood Lipid Analyzer demonstrates impressive precision through its
repeatability evaluation. The following requirements ensure reliable results:

Total Cholesterol (TC): The detection range for TC is 2.59 to 12.93 mmol/L. The
coefficient of variation (CV) should be within 7.5%.
Triglyceride (TG): For TG values below 1.33 mmol/L, the standard deviation (SD)
should be less than or equal to 0.10 mmol/L. For values greater than 1.33
mmol/L, the CV should be within 7.5%.
High-density Lipoprotein Cholesterol (HDL): The detection range for HDL is 0.39
to 2.59 mmol/L. The standard deviation (SD) should be less than or equal to
0.25 mmol/L.
SOURCE: Import-Export Bulletin Board (https://www.imexbb.com/)
Report Abuse

Post an Offer to Sell

© 1996-2010 IMEXBB.com. All rights reserved.

IMEXBB.com