ATP140 Tissue Processor
Our autotechnicon tissue processor is a state-of-the-art laboratory instrument, meticulously designed for efficient tissue sample processing. With automated controls and superior reliability, it ensures precision and consistency in histopathology procedures.
Description of ATP140 automatic tissue processor in histopathology Protective functions:
If the hanging basket comes into contact with any obstacles when entering the liquid tank during operation, it will return to the first tank so as to protect the tissue from being destroyed.
Special cover used with the multiple gasket seal produces excellent sealing performance, which minimizes the volatilization loss of the liquid.
The special glass cover, sealing strips and double layer active carbon filter ensure that the air in the room is not contaminated.
The large screen LCD shows the operating conditions clearly.
Manual operation can be used at will during running to adjust the processing time and improve the processing effect.
In-built UPS can prevent the tissue being stuck in the air or 100% ethanol or xylene for an extensive period of time, destroyed in the event of power failure.
Protection functions for power failure:
You can set which tank is the protecting tank according to your requirement. When power failure lasts more than 5 minutes, the basket automatically enters the protection tank.
When the basket moves into or in front of the protecting tank, if power cut lasts for 5 spacing minutes, the basket stays in the current liquid tank, and shall continue to operate as per the original process until power-on.
When the basket moves between the protecting tank and wax tank, if power cut lasts more than 5 minutes, the basket shall enter the protecting tank, and shall continue to operate as per the original process until power-on.
When the basket moves to wax tank, if power cut lasts more than 5 minutes, the basket shall enter the wax tank, and shall continue to operate as per the original process for one hour with the temperature of wax was raised to your set temperature.
Specification of ATP140 fully automated tissue processor Power supply 220V±10%, 50Hz / 110V±10%, 60Hz Fuse 220V:5AUPS:2A/110V:8A UPS:3A Power 466W Outside dimensions(mm) 1235X475×590(W*D*H) Weight 70 kgs
For more information about tissue processor use and histopathology lab instruments, please feel free to contact us!
If you are looking for a reliable tissue processor manufacturer, don't hesitate to contact us!